Technical data
13
Technical data
Item number:
Dimensions (width x height x depth)
Weight:
Power supply:
Refrigerant extraction rate:
Vacuum pump output:
Hermetic compressor output:
Drier filter output:
Vacuum pump oil service life:
Filling cylinder accumulator capacity:
Noise emission*:
Accuracy of the electronic scale for refrigerant:
Accuracy of the electronic scale for old/new oil:
Accuracy of the electronic scale for UV additive:
Maximum permissible pressure:
Refrigerant:
Oil:
Maximum permissible operating temperature:
Storage temperature range:
* In accordance with DIN EN ISO 3746, the workplace-related emission value LpA of an
air-conditioning service station was determined in various operating conditions. Both the
average dB(A) values and the maximum dB(C) peak values are well below the maxi-
mum permissible exposure values.
Measurements: 62 dB(A), 74 dB(C)
142
ASC5500G RPA 2020
AirConServiceCenter
ASC 5500 G RPA 2020
9103301896
560 mm x 1300 mm x 650 mm
100 kg
220 V/240 V–50 Hz/60 Hz
30 kg / hr
5 cars / hr
0.32 kW
150 kg
60 h
16 kg
62 dB(A)
± 10 g
± 1 g
± 1 g
–1 bar to +20 bar
R-1234yf
any refrigerating unit oil used in
the motor vehicle sector
+5 °C to +40 °C
–25 °C to +50 °C
EN