9. Enter the refrigerant quantity and press ENTER to confirm.
✓ The entry has been created.
You can now create another entry (use the cursor keys to select and
proceed as described) or press "STOP" to exit the menu.
The entries are stored chronologically (not alphanumerically).
8.5
Transferring the consumption of refrigerant onto a
USB stick
Each time a suction or filling process (single process or fully automatic) is
completed, the station stores all the data in the internal memory. A report
can be generated using this data and transferred to a USB stick.
I
NOTE
The USB stick must be formatted with the FAT32 file system.
Each report is saved in two formats:
 as an HTML file (to be opened with any internet browser)
 as an XLS file (to be opened with Microsoft Excel)
I
NOTE
The report may contain a logo (e.g. the workshop logo) if a graphic is
copied to the USB flash drive that meets the following requirements.
 File format: JPEG format
 File name: logo.jpg (note upper and lower case)
 Screen size: 370 x 50 pixels
The company address in the report is taken from the station (see chap-
ter "Entering company data" on page 93).