• Do not connect the system to an unregulated city water system or other external source of pressurized water
producing pressures greater than 35 PSI.
• Trapped air in system can cause the filter lid to be blown off, which can result in death, serious personal injury,
or property damage. Be sure all air is out of the system before operating.
To minimize the risk of severe injury or death, the filter and/or pump should not be subjected to the piping system
pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements are
generally not intended to apply to the pool equipment such as filters or pumps.
Zodiac
pool equipment is pressure tested at the factory.
®
However, if the WARNING cannot be followed and pressure testing of the piping system must include the filter
and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and
secured before testing.
• RELEASE ALL AIR in the system before testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100°F (38°C).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
NOTICE: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult equipment
manufacturer.
Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to
fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment.
Do not start pump dry! Running the pump dry for any length of time will cause severe damage and will void the
warranty.
This pump is for use with permanently installed pools and may also be used with hot tubs and spas, if so marked.
Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building
such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily
disassembled for storage and reassembled to its original integrity.
Do not install within an outer enclosure or beneath the skirt of a hot tub. The pump requires adequate ventilation to
maintain air temperature at less than the maximum ambient temperature rating listed on the motor rating plate.
In order to avoid premature failure or damage to the pump motor, protect the pump from direct water exposure
from sprinklers, water runoff from rooftops and drainage, etc.. Failure to comply may cause pump failure, and may
also void warranty.
Jandy
VS FloPro™ Variable-Speed Pumps
®
WARNING
WARNING
WARNING
CAUTION
CAUTION
CAUTION
SAVE THESE INSTRUCTIONS
|
Installation & Operation Manual

Publicité

Table des Matières
loading

Table des Matières