Jandy
VS FloPro™ Variable-Speed Pumps
®
NOTE
The pump is NSF-certified as being able to prime
at heights up to 10 ft above the pool water level, at sea
level. However, to achieve better self-priming, install the
pump as close as possible to the water level of the pool.
7.
If the pump does not prime and all the instructions
to this point have been followed, check for a
suction leak. If there is no leak, repeat Steps 2
through 7.
8.
For technical assistance, call Zodiac
Support at 800.822.7933.
Section 5. Service and
Maintenance
To avoid damage to the plastics, do not use lubricant
or sealant on the o-ring. Only soapy water should be
used to install and lubricate the o-ring.
5.1
To Remove Pump Lid
1.
Make sure that the pump is turned off.
2.
Make sure that the switch to the circuit breaker that
powers the pump motor is turned off.
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the variable-
speed pump electrical circuit, and allow 5 minutes, before
starting the procedure. Failure to comply may cause a
shock hazard resulting in severe personal injury or death.
ELECTRICAL SHOCK HAZARD
Due to the potential risk of fire, electric shock, or
injuries to persons, Zodiac® Pumps must be installed
in accordance with the National Electrical Code
(NEC
), all local electrical and safety codes, and
®
the occupational Safety and Health Act (OSHA).
Copies of the NEC may be ordered from the National
Protection Association, 470 Atlantic Ave., Boston,
MA 02210, or from your local government inspection
agency.
In Canada, Zodiac Pumps must be installed in
accordance with the Canadian Electrical Code (CEC).
3.
Make sure all necessary isolation valves are closed
to prevent pool water from reaching the pump.
4.
Following the markings on the locking ring, turn
the ring counter-clockwise until the 'START'
|
Installation & Operation Manual
Technical
®
CAUTION
WARNING
WARNING
®
ENGLISH
markings align with the ports. See Figures 13 and
14.
5.
Carefully remove the lid with locking ring.
Lid with
Locking
Ring
Figure 13. O-ring in Lid Assembly
Lid with
Locking
Ring
and
Seal
Pump
Debris
Trap
Basket
(Inside
Pump)
Figure 14. Exploded View of Pump
5.2
Clean Pump Filter Basket
Inspect the pump filter basket for debris by looking
through the clear pump lid. Remove any debris, because
as debris accumulates, it will begin to block the flow
Page 15
Seal