VS FloPro™ Variable-Speed Pumps
®
VS FloPro Controller Options
The VS FloPro pump can be operated by one (1) of five
(5) controllers: the JEP-R variable-speed controller,
iQPUMP01 controller, the AquaLink RS controller (Rev
O or later), the AquaLink PDA (Rev 4.0 or later), or
the AquaLink Z4. The VS FloPro variable-speed pump
communicates with the controllers via a four-wire
RS-485 interface.
Controller Installation Options
The VSFHP085JEP and VSFHP165JEP pumps
come pre-configured for the JEP-R variable-speed
controller with DIP switch settings pre-configured to
work with this controller. The VSFHP085AUT and
VSFHP165AUT Pumps come pre-configured for
installation with the AquaLink RS, AquaLink PDA, or
AquaLink Z4.
To install with an AquaLink RS controller (Rev O
or later), an AquaLink PDA (Rev 4.0 or later), or an
AquaLink Z4:
1.
Remove power from the VS FloPro pump by
disconnecting the high voltage lines or by turning
off any breaker to which the VS FloPro pump
power is connected.
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the variable-
speed pump electrical circuit, and allow five (5) minutes,
before starting the procedure. Failure to comply may cause
a shock hazard resulting in severe personal injury or death.
2.
Remove the access cover to complete electrical
connections to the motor.
3.
Slide DIP switches 1 and 2 down to the OFF
position. Slide DIP switch 5 up to the ON position.
See Figure 7.
4.
Select the desired address(es) for the pump by
setting DIP switches 3 and/or 4, as shown in Section
3.3, VS FloPro Pump DIP Switch Settings.
5.
If short RS-485 cable or JEP-R controller is pre
installed:
a. Disconnect the RS-485 cable from the 4-pin
header on the pump drive.
Note: Do not cut the cable, or you will lose the ability to return
to the default factory configuration.
b. Connect the new RS-485 cable from the
AquaLink through the available compression
fitting and route the 4-conductor cable through
the motor drive threaded port closest to the
connector. Figure 7.
6.
Connect the RS-485 connector on the
AquaLink
RS (or multiplexer interface board),
®
matching wire colors with connector positions as
follows: 1-red, 2-black, 3-yellow, and 4-green. See
Figure 7.
|
Installation & Operation Manual
WARNING
ENGLISH
7.
Secure wiring access cover to the pump motor.
8.
Restore power to the pump and verify the operation
of the controller.
9.
Refer to the appropriate manual for set up and
operation of the pump: AquaLink RS Owner's
Manual, 6593, AquaLink PDA Owner's Manual,
H0572300, or AquaLink Z4™ Owner's Manual,
H0386600.
AquaLink
RS RS-485 Connectors
®
S1
S2
5-Position
DIP Switch
200 ft (61 m)
max install distance
for communication
Figure 7.
Wiring AquaLink RS Controller or
AquaLink PDA
Page 11
4 3 2 1
4 3 2 1
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
RS6 & RS8 ONLY
RS8 ONLY
RESET
POOL MODE
SPA MODE
AUTO
SPA DRAIN
SERVICE
HEATER
SOLAR
SPA FILL
TIME OUT
Connect to
AquaLink RS
4 3 2 1
RS-485 Connector
(or Multiplexer
Interface Board)
Variable-Speed
Pump
Power Wiring Port
Product may differ from images shown