05-351 / 05-352 / 05-336 / 05-300
4.7. Table of time functions
The time function is defined with the 'time' rotary switch.
TIME SETTINGS:
For switch functions
Times
Switch-
off time T
0
0
1
0,5''
2
2''
3
4''
4
6''
5
10''
6
20''
7
30''
8
1'
9
3'
A
5'
B
7'
C
9'
D
15'
E
45'
F
120'
64
Control
Operating
time T2
time T4
0
no limit
1,5''
150''
3''
90''
0
30''
0
15''
0
0,4''
0
no limit
0
150''
0
90''
0
30''
0
15''
0
no limit
0
150''
0
90''
0
30''
0
15''
For shutter/ventilator control
Control
time T3
0
0
slow rolling blind control
0
0
0
0
pulsed rolling blind control
1,5''
1,5''
1,5''
1,5''
1,5''
3''
3''
3''
3''
3''
Remarks
ventilator control
rolling blind control
rolling blind control
rolling blind control
ventilator control
ventilator control
rolling blind control
rolling blind control
rolling blind control
ventilator control
ventilator control
rolling blind control
rolling blind control
rolling blind control
EN