General Points; Applications; Pumped Fluids; Technical Data And Use Limitation - ARVEN KONTRACT180 1 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47

1 GENERAL POINTS

Read this documentation carefully before installation.
Installation and functioning must comply with local and national safety regulations in force in
the country where the product is to be installed.
The entire operation must be carried out in a workmanlike manner.
Failure to comply with the safety regulations not only causes risk to personal safety and da-
mage to the equipment, but also invalidates any right to warranty assistance.
Keep this manual in a safe place for further consultation even after the first
installation.

2 APPLICATIONS

These electropumps are suitable for collecting rainwaters, waste waters containg abrasives;
ideal for DRAINING DOCKYARDS, shafts and emptying basements and garages.The pumps
be also employed in moderately charged moving waters, irrigation plants, and layer waters.
When installed in wells or tanks, the pump, which is particularly silent running, avoids all pro-
blems related to suction and loss of priming.
The pump may be supplied with a float switch cutting out operation automatically in the event
of an insufficient water level.
These pumps cannot be used in swimming pools, ponds or tanks in which people are
present, or for pumping hydrocarbons (petrol, diesel fuel, fuel oils, solvents, etc.) in
accordance with the accident-prevention regulations in force.
N.B. : The liquid employed in the pump for lubricating the sealing device is not toxic, but it
could alter the water properties (in the case of pure water) if there were any leaks in the seal.

3 PUMPED FLUIDS

The machine has been designed and built for pumping water, free from explosive substances,
and solid particles or fibres, with a density of 1 Kg/dm3 and a kinematic viscosity of 1mm2/s,
and chemically non-aggressive liquids.
4 TECHNICAL DATA AND USE LIMITATIONS
- Supply voltage:
- Absorbed power:
- Maximum ,working pressure:
- Pumped fluid:
- Degree of motor protection:
- Thermal class:
- Liquid temperature range:
- Maximum immersion:
- Storage temperature:
- Noise level:
-Motor constructions:
see electric data plate
see electric data plate
2,2 Bar
clean, free from solids and abrasive substances;
non aggressive.
IP 68
F
from 0°C to 35°C
5 metres
from -10°C to +40°C
noise level is contained within the limits envisaged by EC
Directive EC 89/392/CEE and subsequent modifications.
in accordance with CEI 2-3 - CEI 61-69 (EN 60335-2-41)
standards.