Your Direct Vent Wall Furnace is shipped complete in one carton. This carton contains the furnace, vent cap, collector box, vent
exhaust tube, air inlet tube, wall template with rough-in dimensions, installation and operating instructions, and wall thermostat.
MODEL NUMBERS
Gas Type
Height
Width
Depth
Input (BTU / HR)
Type of Control
Cubic Feet per Minute (CFM)
AMPS
Gas Connection
Center Vent to Floor (Adj.)
Min.–Max. Wall Thickness
Approximate Weight
THIS IS A GAS-FIRED DRAFT INDUCED, POWER DEPENDENT DIRECT VENT WALL FURNACE THAT WILL OPERATE
SAFELY AND PROVIDE AN EFFICIENT SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS
RECOMMENDED IN THESE INSTALLATION AND OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING, SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART
OF THESE INSTRUCTIONS CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLER, SERVICE TECHNICIAN,
THE GAS SUPPLIER OR THE MANUFACTURER.
1.
Improper installation, adjustment, alteration, service,
or maintenance can cause property damage, bodily
injury, or death.
2.
Use in other than a residential application may result
in unsatisfactory performance, may create unsafe
conditions and will invalidate the warranty.
3.
The installation must conform with local codes or in
the absence of local codes wtih the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and
Propane Installation Code, CSA B149.1.
4.
DO
NOT
INSTALL
RECREATIONAL VEHICLE OR TRAILER.
5.
Do not operate wall furnace unless it is connected to
the factory supplied vent system with vent cap in place.
6.
Check the rating label attached to the wall furnace to be
sure it is equipped for the type gas you intend to use.
7.
Never use a match, candle, flame or other source of
ignition to check for gas leaks. Use only soapy water
or liquid detergent.
SPECIFICATIONS & DIMENSIONS
HEDV253A
Natural
32-1/4"
24-1/2"
9-3/4"
25,000
24 V.
200
1.88
3/8"
12-1/2"
35" – 2"
100 lbs
INTRODUCTION
THIS
FURNACE
IN
HEDV403A
Natural
30-1/2"
34-5/8"
9-3/4"
40,000
24 V.
500
2.18
3/8"
12-1/2"
35" – 2"
120 lbs
SAFETY
8.
Have your wall furnace and vent system inspected at
least annually by a qualified service technician.
9.
Before cleaning or servicing, turn off the gas and
allow furnace to cool.
10. Do not operate wall furnace without all components
properly installed (top, front, etc.).
11. Due to high temperatures, the appliance should be
located out of traffic and away from furniture & drapes.
12. Children and adults should be alerted to the hazards
of high surface temperature and should stay away to
A
avoid burns or clothing ignition.
13. Young children should be carefully supervised when
they are in the same room as the appliance.
14. Clothing or other flammable material should not be
placed on or near the appliance.
15. INSTALLATION AND REPAIR SHOULD BE DONE
BY A QUALIFIED SERVICE TECHNICIAN. THE
APPLIANCE SHOULD BE INSPECTED BEFORE
Page 3
HEDV254A
HEDV404A
Propane
Propane
32-1/4"
30-1/2"
24-1/2"
34-5/8"
9-3/4"
9-3/4"
25,000
40,000
24 V.
24 V.
200
1.88
3/8"
12-1/2"
12-1/2"
35" – 2"
35" – 2"
100 lbs
120 lbs
500
2.18
3/8"
1017952-A