Operating Instructions; Maintenance And Storage - Mr. Heater MH25CVX Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

OPERATING INSTRUCTIONS

PREPARING FOR OPERATION
1.
Extend the shell fully and lock into place as shown in the
enclosed instructions sheet before lighting or operating
the heater.
2.
Check the heater for possible shipping damage. If any is
found, immediately notify the factory.
3.
Follow all of the Safety and Operating Precautions.
4.
Connect the POL fitting of hose and regulator assembly
to the propane cylinder by rotating the POL nut
counterclockwise into the propane cylinder's valve outlet
and securely tighten with a wrench.
5.
Connect the hose to the heater.
6.
Securely tighten all gas connections.
7.
Open the cylinder's gas valve and check all gas connections
with a soap and water solution. DO NOT USE A FLAME.
STARTING (200CVX)
1.
WARNING: BEFORE LIGHTING PILOT, turn main burner
valve (turn knob fully clockwise) to low/light position.
2.
Fully open the valve on the propane cylinder and wait 15
seconds before Step 3.
3.
Depress red button on safety pilot valve (to the right of
the variable valve knob) admitting gas to the pilot. Then
push and release the ignition button (red button to the
right of the variable valve knob) until the pilot lights.
4.
When the pilot lights, continue to hold the button
depressed for 30 seconds, then release to light main
burner.
5.
If pilot goes out, wait 5 minutes and repeat the lighting
procedure.
6.
Turn main burner valve to regulate heat output.
STARTING (25CVX, 80CVX)
WARNING: BEFORE LIGHTING PILOT, turn main burner
1.
valve (turn knob fully clockwise) to low/light position.
2.
Fully open the valve on the propane cylinder and wait 15
seconds before Step 3.
3.
Push knob in and hold for 5 seconds, allowing gas to emit
from burner orifice.
4.
Rotate the knob counterclockwise until the piezo igniter
clicks. Continue to rotate and activate the igniter until the
burner lights.
5.
Once the burner lights hold the knob in, on the low
position for 30 seconds. Then release. The burner should
stay lit. If it does not repeat steps 4&5 until the burner
stays lit.
6.
Turn main burner valve to regulate heat output.
6
Convection Construction Heater
STOP (All UNITS)
1.
Securely close valve on the propane cylinder.
2.
Continue to operate heater until all fuel in the hose has
burned.
3.
Turn main burner valve to lo/light position.
RESTART AFTER SAFETY SHUTDOWN
1.
Securely close valve at propane cylinder.
2.
Wait 5 minutes.
3.
Restart following "Start" procedure for your model.

MAINTENANCE AND STORAGE

1.
The heater should be inspected before each use, and at
least annually by a qualified person.
2.
Before each use, check the soft "O" ring seat at the
bullnose of the POL fitting. If the "O" ring is cut, scuffed, or
otherwise damaged, replace it with part number F273786.
3.
Turn off the gas at the LP-gas supply cylinder(s) when the
heater is not in use.
4.
When the heater is to be stored indoors, the connection
between the LP-gas supply cylinder(s) and the heater
must be disconnected and the cylinder(s) removed from
the heater and stored out of doors and in accordance
with Chapter 5 of the standard for Storage and Handling
of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA
B149.1,Natural Gas and Propane Installation Code.
SERVICING
A hazardous condition may result if a heater is used that has
been modified or is not functioning properly. When the heater
is working properly:
* The flame is contained within the heater.
* The flame is essentially yellow with some blue at the base of
the fame adjacent to the burner.
* There is no strong disagreeable odor, eye burning or other
physical discomfort.
* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the
heater.
The parts lists and exploded view show the heater as it was
constructed. Do not use a heater which is different from
that shown. In this regard, use only the hose, regulator and
cylinder connection fitting (called a POL fitting) supplied with
the heater. IMPORTANT Match the color stripe on the hang
tag attached to the hose assembly with the color on the label
located near the propane inlet fitting on the heater. Do not
use alternates. For this heater, the regulator must be set as
shown in "specifications". If there is any uncertainty about the
regulator setting, have it checked.
A heater which is not working right must be repaired, but only
by a trained, experienced service person.
In-warranty products will be repaired with no charge for either
parts or labor. Please include a brief statement indicating date,
place of purchase, the nature of the problem and proof of
purchase.
Out-of-warranty products will be repaired with a charge for
parts and labor.
Operating Instructions and Owner's Manual

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Mh80cvxMh200cvx

Table des Matières