Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DIMENSIONS

Figure 1
Maximum hydrostatic water pressure - 1.03 MPa (150 p.s.i.)
Maximum recommended working pressure - 0.69 MPa (100 p.s.i.)
Minimum working pressure - 0.0138 MPa (2 p.s.i.) at 2 Litres/min. (0.5 U.S. gals./min.).
DIMENSIONS in Milimetres (inches)
Model
milimetres
WR 400-3.K..
inches
Model
Type of Gas
natural
propane/LP
WR 400-3.K..
natural
propane/LP
* The high altitude ratings listed are Canadian Gas Association high altitude ratings and are valid only in Canada.
In the U.S., the National Fuel Gas Code, ANSI Z223. 1 -1988, recommends for high altitude installations above
2,000 feet, that the input rate be reduced 4% for each 1,000 feet above sea level. - See page 8.
2
Dimensions
A
460
18 1/8
Altitude
standart
(0-2,000 ft.)
high *
(2,000-4,500 ft.)
B
D
diam
755
130
diam
29 3/4
5 1/8
Input
34.28 kW
(117,000 Btu/hr)
30.85 kW
(105,000 Btu/hr)
E
F
740
542
29 1/8
21 11/32
Main Burner Orifices
Size, mm
Qt.
1.20 diam.
18
0.79 diam.
18
1.20 diam.
18
0.79 diam.
18

Publicité

Table des Matières
loading

Table des Matières