Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
Important Information
General
These Installation instructions contain
important Information which must be
observed in order that the extractor hood can
be installed and operated without risk or
difficulties.Keep these Installation instructions
in a safe place for subsequent use. Follow
the instructions of the cooking appliance
manufacturer for Installation of extractor
hoods. The assistance of another person will
facilitate Installation.Replace defective parts
with original spare parts or with parts named
by the manufacturer.
Note: If extractor hoods feature external fan
motors, the Installation of the fan motor can
be found in separate installation instructions.

Safety instructions

Danger
Installation, connection, startup and repairs
may be carried out by technicians only.
Technicians can specify a suitable attachment
and exhaustair conduction for the extractor
hood.The attachment must be suitable for the weight
of the extractor hood and for the load on the
wall. Observe the pullout values of the
supplied wall plugs. These have the following
values depending on the wall:
10 mm wall plugs:
Concrete B25
Brick MZ20
Solid calcium silicate brick KSV20 4.8 kN
If the wall is made of other uncertain
materials, consult a building specialist, e.g.
a structural engineer or an architect to ensure t
hat the extractor hood can be installed securely.
Risk of injury
The hood structure may have sharp edges
caused by the manufacturing process. Wear
protective gloves during installation.
Risk of electric shock
The mains voltage must correspond with the
specifications on the rating plate. The rating
plate is situated near the filters inside the
hood.Connect the extractor hood to a
correctly installed earthed socket only. The
socket must be easily accessible following
instal-lation so that the extractor hood can
be isolated if required. If the extractor hood
is to be permanently connected (e.g. if there
is no appropriate socket), it may be connected
to the mains by an electrician only. If the
extractor hood is to be permanently
connected, it must be connected to a single
electric circuit with disconnector. Switches
with a contact opening of at least 3 mm and
all-pole switches, e.g. LS switches and
contactors, are regarded as disconnectors.
Before connecting the extractor hood to the
power supply, disconnect the mains circuit(s).
Before drilling fixing holes, ensure that there
are no electric cables which could be
damaged by the drilling. When preparing the
power supply connection, ensure that the
extractor hood can be connected without difficulty.
Observe local regulations.
Exhaust-air conduction (for exhaust-air mode)
The exhaust air must not be conducted into
a chimney which is used to remove exhaust
gases from appliances which use fuel (e.g.
gas). Observe the official regulations for the
removal of exhaust air. When preparing the
exhaustair route, ensure that the extractor
hood can be connected without difficulty. The
exhaustair hose must not be kinked.
9.4 kN
Solid fuel fireplaces
5,2 kN
The extractor hood must not be installed
above a solid fuel fireplace which is a fire
hazard (e.g. flying sparks) unless the fire-
place has a sealed, non-removable cover.
Minimum distance from an electric cooking appliance.
Minimum distance from a gas cooking appliance
Minimum distance between the lower edge
of the extractor hood and hotplates/ hobs is
min. 650 mm. If the manufacturer of the gas
cooking appliance specifies a greater
distance, this must be taken into consideration.
en

Publicité

Table des Matières
loading

Table des Matières