Adjustments
C
- SENS. Trimmer = Amperometric device sensitivity (min. / max.)
- TCA Trimmer = Automatic closing time min 1 sec. - max. 120 sec.
Connection of two pairs of barriers with a single command
1) Designate the Master barrier (or pilot, namely the motor that commands both barriers) and the Slave (motor piloted by the Master).
2) On the command board designated as the Master, execute all the wiring connections, the installation procedure for remote control,
settings and regulations.
On the command board designated as the Slave, position the dip 7 to ON; make the connections to the power supply on the L-N terminal,
connect the device to the output of the 10-E terminal, adjust the speed of motion and the slowdowns of the Master barrier.
3) Execute the connection between the two command boards using the RX-TX-GND terminals.
Activating the remote control
-Connect the antenna's RG58 cable to the apposite terminals.
-Lock the radiofrequency card into the electronic card
N.B.: the electronic card only recognises the radiofrequency card when the power is on.
Memorisation
A
-Keep the "PROG"
button on the electronic card pressed. The LED fl ashes.
-Press the transmitter button you wish to memorise. The LED will stay on to show memorisation has been successful.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
D
AFTER CUTTING OFF THE POWER SUPPLY (or after disconnecting the batteries).
B