Inspect for damage. If any damage is noted, report damage to the freight company and contact distributor
at the address shown on the cover.
Verify that the unit marking plate indicates that the unit is set up for service on the type of gas fuels as
found at the installation site. Natural gas units have to be operated on natural gas only and propane units
used only on propane gas.
Plan location of units in such a manner as to be best accessible to operator. Locate unit so that foot traffic
in area will not interfere with unit operation. When choosing unit location, take into consideration the
operation of overhead and side mounted heating/cooling ducts and fans.
VENTILATION
The area in which the appliance is to be installed should have sufficient fixed ventilation to comply with
local requirements, with a minimum area of 4.5 cm per 1Kwht (3412 Btu per hr) of total heat input.
Ventilation hood must be installed above the appliance according to all appliance codes by your local and
state health and fire regulations.
It is required that the Tandoor be interlocked to the hood ventilation system.
There must be sufficient low- level ventilation to ensure that the appliance has a good supply of clean fresh
air.
GAS SUPPLY AND CONNECTION
Check that the gas supply correspondence to that on data plate. Gas connection must be the same size
of the Baba Clay Oven, BSP ½", (For U. S. A. and Canada NPT ½"). Inlets. Warning: Do not under any
circumstances join NPT to BSP threads when making connections.
The ½" connection for connection of gas supply is located behind the unit.
A shut off valve should be installed on the gas service line ahead of the unit in case of emergency and
for serving purposes. The location of the manual shutoff valve should comply with codes in effect at the
installation site.
Since the appliance is caster mounted, connection of the appliance must be made using suitable flexible
connection devices. Ensure that the hose is suitable for commercial catering appliances and a restraining
wire and wiring label are used.
Fixed pipe work must not be used with this appliance.
For the U. S. A. and Canada - Installation shall be made with a connector that complies with the standard
for connectors for Movable Gas Appliance, ANSI Z21.69-CSA 6.16, and a quick Disconnect devices for the
use with gas fuel, ANSI Z21.41- CSA 6.9.
Connect tandoor to gas supply and conduct gas leakage tests to verify gas tight connections. Check entire
piping system for leaks. A solution consisting of 50% dish washing detergent and water mix can be applied
to all piping parts with a brush.
Matches, candles or other sources with open flames or sparks shall not be used for this purpose. Gas
controls are provided with outlet settings suitable for the fuel type shown on the name plate. Adjustments, if
needed, to the regulator should only be made by qualified service staff. The regulator outlet pressure must
be the pressure shown on the name plate for the type of gas fuel used.
Some local codes require that a manual shutoff valve be installed in the same room and within six feet of
the appliance. If because of local code requirements, a manual gas shutoff valve has to be installed on the
appliance, and if it is mounted inside of enclosure by access doors, a label should be provided indicating
9