Technical Parameter - Hayward HP55BEE Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

III.

Technical Parameter

Model
Voltage
Frequency/phase
Heating current(air80°F,water80°F)
Heating power(air80°F,water80°F)
Compressor MRC
Fan motor rating
MCA/MOP
Design pressure(High)
Design pressure(Low)
Refrigerant(R410A)
Net weight
Water circulation flow
Noise
Waterproof class
Notice:
1.
This product works well under water temp 80
o
109
F, efficiency will not be guaranteed out of this range. Please take into
consideration that the pool heater performance and parameters are different under
various conditions.
2.
Related parameters are subject to adjustment periodically for technical
improvement without further notice. For details please refer to nameplate.
HP55BEE
208-230V
60Hz/1Ph
1.2~10.8A
0.24~2.38kW
12A
0.45A
15.5A/25A
≤609 PSIG
≤261 PSIG
42.3oz
1834oz
83-117L/min
≤50 dB(A)
IPX4
o
o
F to104
F, air temp 19.4
HP65BEE
208-230V
60Hz/1Ph
1.9~12.8A
0.38~2.8kW
18A
0.8A
23.3A/40A
≤609 PSIG
≤261 PSIG
49.4oz
2400oz
108-150L/min
≤50 dB(A)
IPX4
o
F to
5

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hp65bee

Table des Matières