Napoleon Ascent Série Manuel D'installation page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

venting requirements
EN
Special vent installation (periscope termination)
Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when
cope kit to locate the air termination above grade. The periscope must be installed so that
final grading is completed, the bottom air slot is located a minimum 12" (30.5cm) above grade. The maximum
ding is completed, the bottom air slot is located a minimum 12" (305mm) above grade. The
allowable vent length is 10' (3m) for a fireplace and 8' (2m) for a stove.
wable vent length (including both rise and run) is 10' (3m) for a fi replace and 8' (2m) for a stove.
sleeve is illustrated in the top vent image below, use only when supplied with the appliance.
n sleeve is not required with a stove appliance)
REAR VENT
14
W415-1705 / 06.07.17
30" (76.2cm)
minimum
33 1/8"
(84.1cm)
TOP VENT
8.1
12"
(30.5cm)
minimum
to grade

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ascent bl36-1Ascent bl46

Table des Matières