Chart 1 Troubleshooting
PROBLEM
Camera video image not
seen.
Flashing Battery
Warning appears.
LT1000 video freezes.
No video.
PROBABLE FAULT LOCATION
No power to SeeSnake.
Connections faulty.
Batteries Low.
LT1000 18 V batteries low.
Low-quality AC power or voltage spike.
If your computer doesn't recognize the USB
connection.
Do not start your computer with the LT1000 turned
ON.
SeeSnake
®
LT1000
SOLUTION
Check power is correctly plugged in or battery is
charged.
Check Power Key on LT1000 by pressing.
Check connection to LT1000 unit from SeeSnake.
Check seating and pin condition in the SeeSnake
System connection. Clean if needed.
Recharge batteries or connect external power sup-
ply.
Recharge LT1000 batteries. Switch to AC power
(110/240VAC).
Power cycle the LT1000 OFF and then ON.
Restart your computer, power cycle LT1000 or
close HQ and restart it to see if this corrects the
problem.
The LT1000 should be turned OFF, though it's ok
to have the USB cable plugged in.
NOTE: The USB connector (see Figure 12) on the
LT1000 was designed to be a water-resistant seal,
so it is a tight fit. Your LT1000 was tested and
shipped with this cable firmly connected. If you
need to disconnect and reconnect this cable (for ex-
ample, if you break your USB cable), make sure
you push the connector in all the way. If you don't,
the HQ software might not recognize the LT1000.
If so, make sure you have pushed the connector in
all the way. You may have to restart HQ to recog-
nize the connection.
17