SeeSnake
The LT1000 Mini is a sturdy portable frame supporting an
LT1000 unit. It is light-weight, easy-to-carry and can be
used with any SeeSnake reel simply by connecting the
SeeSnake System Cable. It is an economical alterna-
tive if you need to shift your LT1000 between SeeSnake
reels frequently. The LT1000 Mini is shipped with the
LT1000 unit already installed on the portable frame.
Preparing the Laptop
To operate correctly with the LT1000, the laptop to be
used must have SeeSnake HQ software installed on it.
HQ software enables you to create, manage and store im-
ages, audio and video from the LT1000. The software is
on the CD that ships with the LT1000. To load the soft-
ware from the CD:
You must install SeeSnake HQ and its drivers before
connecting the LT1000 to your computer.
1. Insert the CD into the computer's CD drive.
2. The laptop should auto-detect the CD and begin the
installation process. It may ask for an admin password
before installing the HQ software.
3. When the software installation is complete, eject the
CD and store it in a safe place.
NOTE! Software update checks will occur automatically
when the laptop is connected to the Internet. If an
update is detected you will be asked if you want
to install it, and the update will occur automatically
if you indicate you want it installed. The latest ver-
sion can be checked for manually by placing the
laptop on-line and pointing an Internet browser to
http://www.hq.ridgid.com/product-hq.php .
4. Alternatively the software may be installed by brows-
ing to the updates website given above and following
the instructions found there.
5. For detailed instructions on using HQ software to
manage your video clips, still photos, reports, cus-
tomer information and formats, direct a web-con-
nected browser to http://www.hq.ridgid.com/. You
will find on-line user instructions for every aspect of
HQ's capabilities there.
10
®
LT1000
Pre-Operation Inspection
WARNING
Before each use, inspect your SeeSnake LT1000
and correct any problems to reduce the risk of se-
rious injury from electrical shock or other causes
and prevent machine damage.
1. Confirm that the power is OFF, any external power
and cords are disconnected and the battery is re-
moved. Inspect the cords, cables and connectors
for damage or modification.
2. Clean any dirt, oil or other contamination from the
SeeSnake LT1000 to aid in inspection and to prevent
the unit from slipping from your grip while transporting
or using.
3. Inspect the LT1000 for any broken, worn, missing, mis-
aligned or binding parts, or any other condition which
might prevent safe, normal operation. Ensure the
LT1000 mounting brackets are securely tightened.
4. Inspect any other equipment being used per its in-
structions to make sure it is in good usable condition.
5. If any problems are found, do not use the unit until the
problems are corrected.
Work Area and Equipment
Set Up
WARNING
Set up the LT1000 and work area according to
these procedures to reduce the risk of injury from
electrical shock, fire and other causes, and to pre-
vent damage to the LT1000.
1. Check work area for:
• Adequate lighting.
• Flammable liquids, vapors or dust that may ignite.
If present, do not work in area until sources have
been identified and corrected. The LT1000 is not