TECHNICAL SPECIFICATIONS

Measuring range:
• Calibration Accuracy;
• Operating Environnement
• Storage / Transport Environnement
• Power source:
• Weight:
• Dimensions :
• Cuff Circonférence (M-L size) :
EMC TABLES
Emissions test
Compliance
RF Emissions
Group 1
CISPR 11
RF Emissions
Class B
CISPR 11
Harmonic Emissions
Not
CEI 61000-3-2
applicable
Voltage variations /
Not
Flicker emissions
applicable
CEI 61000-3-3
EMC TABLES
Immunity Test
Electrostatic Discharge
± 6 kV
(DES)
contact
CEI 61000-4-2
± 8 kV air
Power Supply
Frequency (50/60 Hz)
3 A/m
Magnetic Field
CEI 61000-4-8
Manufacturer's declaration and directive – electromagnetic emissions
The 0075N arm blood pressure monitor is intended for use in the electromagnetic environment
specified below. The client or user of the 0075N arm blood pressure monitor must be sure to use it
in such an environment.
The 0075N arm blood pressure monitor uses RF energy only for its internal operation.
Therefore, its RF emissions are very low and are not likely to cause interference in electronic
equipment nearby.
The 0075N arm blood pressure monitor may be used in all establishments, including
dwellings and establishments directly connected to the public low-voltage power supply
system that powers buildings intended for homes.
Manufacturer's declaration and directive – electromagnetic immunity
The 0075N arm blood pressure monitor is intended for use in the electromagnetic environment
specified below. The client or user of the 0075N arm blood pressure monitor must be sure to use it
in such an environment.
Compliance
CEI 60601
Test level
level
± 6 kV
contact
± 8 kV air
3 A/m
Blood Pressure : 30 à 280 mmHg
Pulse rate : 40 à 199 pulse / min
Blood Pressure : ± 3 mmHg
Pulse rate: ± 4% of reading
10°C à 40°C
with relative humidity up to 85% (non
condensing)
-20 °C à + 50 °C
with relative humidity up to 85% (non
condensing)
4 x AA 1,5 V (LR06)
259g (without batteries)
128 mm x 150 mm x 59,2 mm (lx H x P)
22 - 42 cm
Electromagnetic environment guidelines
Guidelines on the electromagnetic environment
The floors must be made of wood, cement or ceramic tiles. If the floors are
covered in synthetic material, relative humidity must be below 30%.
The magnetic field of the supply frequency must be at a level appropriate
to the place of use.
38