Water connection
WARNING
Risk of electric shock and damage to the appliance!
Disconnect the appliance from the power source
before performing any work on the water
connection.
Only a qualified installation technician may connect
the appliance to the water supply in accordance
with plumbing and relevant water utility company
regulations.
Connect the appliance to a drinking water line only:
Minimum pressure:
n
0.17 MPa (1.72 bar, 24.95 PSI)
Maximum pressure:
n
0.82 MPa (8.25 bar, 119.66 PSI)
n
Pressure over 0.82 MPa (8.25 bar, 119.66 PSI):
install a pressure limiter between drinking water
connection and hose set.
The water should be connected only by a competent
plumber according to the local regulations of the
appropriate Water Supply company.
A cold water connection is necessary for operating the
ice maker. The water pressure must be between
0.17 MPa (1.72 bar, 24.95 PSI) and
0.82 MPa (8.25 bar, 119.66 PSI). The installation must
correspond to the local plumbing regulations.
A separate Shut-Off-Valve should be installed in the
cold-water inflow.
It is recommended that you mount the Shut-Off-Valve
directly next to the appliance or at another place that
is easily accessible.
When installing the water connection, pay attention to
the permissible installation area for the water line.
For connection to the drinking water line use only
water pipes that are suitable for drinking water.
Observe national regulations and the connection
conditions of the local Water Supply companies.
8
Electrical connection
WARNING
Risk of electric shock and fire if electrical
connection is not installed properly!
Plug into a fixed, grounded 3-prong outlet only. The
outlet must be installed and grounded according to
code by a qualified electrician. If necessary, have
the installation inspected by a qualified electrician
to ensure it is properly grounded.
Never remove grounding conductor.
Do not use an extension cord, adapters or power
strip.
Non-compliance with these instructions may result
in death, fire or an electric shock. Improper
connection of the grounding conductor may result
in an electric shock. If you are in doubt whether the
appliance has been grounded properly, have the
appliance tested by a qualified electrician.
The receptacle must be installed according to the
Installation Manual.
Connect the appliance to 115 V/60 Hz AC through a
correctly installed 3-pole grounded receptacle. The
receptacle must be protected with a 15 to 20 A fuse.
The appliance comes with a UL registered 3-wire
Power Cord.
Please see the following table:
Appliance
Maximum simultaneous load
Fridge-freezer
6.0 amps
Check on the Rating Plate whether the indicated
voltage and current type correspond with the values of
your power supply. The location of the Rating Plate
can be found in the chapter "Customer Service".
WARNING
Never connect the appliance to electronic energy
saving devices.
This appliance can be used with power line and
sine-controlled inverters. Power line-controlled
inverters are used for photovoltaic systems which
are connected directly to the national grid.
Sine-controlled inverters must be used for isolated
applications (e.g. on ships or in mountain lodges)
which are not connected directly to the national
grid.