Brush Inspection
Remove the plate cover, check the motor brushes after the
first 50 hours of use for a new machine or after a new set of
brushes have been installed. After the first check, examine
them every 10hours of use.
When the carbon is worn to 6mm in length or if the spring or
shunt wire is burned or damaged, replace both brushes. If the
brushes are found serviceable after removing, reinstall them.
Trouble Shooting
PROBLEM
PROBLEM CAUSE REMEDY SUGGESTED
Breaking
1. Wrong tension
blades
2. Over working
blades
3. Wrong blade
application
4. Twisting blade in
wood
Motor is not
1. Defective lead or
run
plug
2. Defective motor
Excess
1. Improper
vibration
mounting of the
saw
2. Unsuitable
mounting surface
3. Loose table or
table resting
against motor
4. Loose motor
mounting
Blade runout
Blade holders not
Blade not in
aligned
line with arm
motion
1. Adjust blade tension
2. Reduce feed rate
3. Use narrow blades
4. Avoid side pressure
on blade
1. Replace defective
parts
2. Consult Service
Centre
1. See Mounting the
Tool to a Bench
2. The heavier your
workbench, the
less vibration occur.
Use common sense
in choosing a
mounting surface.
3. Tighten table lock
handle.
4. Tighten motor
mounting screws.
Loosen cap screws,
holding blade holders to
arms. Adjust position of
blade holders.
Retighten holders.