DISTANCES TO RESPECT IN PREMISES
The boiler was designed for installation at safe
distances from objects and walls.
• Minimum distance in front of the boiler
must be 800 mm to guarantee correct opening
of the door and normal maintenance opera-
tions.
• Minimum distance permitted between the
rear and a wall must be 400 mm.
• Minimum distance between the boiler and
the side walls must be 500 mm.
• Minimum distance between the boiler and
the upper walls must be 1200 mm.
500
INSTALLATION
400
500
800
- 51
-
1200
1360