Section 3 Operation; Operation And Use Questions; Before Starting Engine; Prepare Generator For Use - Generac GP2500i Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 3 Operation

Operation and Use Questions

Call Generac Customer Service at 1-888-
GENERAC (1-888-436-3722) with questions
or concerns about equipment operation and
maintenance.

Before Starting Engine

1. Verify engine oil level is correct.
2. Verify fuel level is sufficient.
3. Verify unit is secure on level ground, with
proper clearance and is in a well ventilated
area.

Prepare Generator for Use

Asphyxiation. Running engines produce carbon
monoxide, a colorless, odorless, poisonous
gas. Carbon monoxide, if not avoided, will
result in death or serious injury.
Asphyxiation. The exhaust system must be properly
maintained. Do not alter or modify the exhaust system
as to render it unsafe or make it noncompliant with
local codes and/or standards. Failure to do so will
result in death or serious injury.
WARNING
Risk of fire. Do not use generator without
spark arrestor installed. Failure to do so
could result in death or serious injury.
WARNING
Asphyxiation. Always use a battery operated carbon
monoxide alarm indoors and installed according to
the manufacturer's instructions. Failure to do so could
result in death or serious injury.
WARNING
Risk of Fire. Hot surfaces could ignite
combustibles, resulting in fire. Fire could
result in death or serious injury.
WARNING
Hot Surfaces. When operating machine, do not
touch hot surfaces. Keep machine away from
combustibles during use. Hot surfaces could
result in severe burns or fire.
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
Owner's Manual for Portable Generator
DANGER
DANGER
(000179b)
(000118a)
(000178a)
(000110)
(000108)
CAUTION
(000136)
Grounding the Generator When
In Use
The generator is equipped with an equipment
ground connecting the generator frame and
the ground terminals on the AC output recep-
tacles (see NEC 250.34 (A). This allows the
generator to be used as a portable without
grounding the frame of the generator as spec-
ified in NEC 250.34. See
• Neutral Floating
(000103)
Figure 3-1.Grounding the Generator
The generator (stator winding) is isolated from
the frame and from the AC receptacle ground
pin. Electrical devices that require a grounded
receptacle pin connection will not function if
the receptacle ground pin is not functional.

Special Requirements

There may be Federal or State Occupational
Safety and Health Administration (OSHA) reg-
ulations, local codes, or ordinances that apply
to the intended use of the generator. Consult a
qualified electrician, electrical inspector, or the
local agency having jurisdiction:
• In some areas, generators are required to
be registered with local utility companies.
• If the generator is used at a construction
site, there may be additional regulations
which must be observed.
Connecting
Electrical System
Use a manual transfer switch when connect-
ing directly to a building electrical system.
Installation and connections must be per-
formed by a qualified electrician and in strict
compliance with all national and local electri-
cal codes and laws.
Always operate the generator with the Eco
Mode Switch OFF (if equipped).
Figure
3-1.
to
a
Building
004468
9

Publicité

Table des Matières
loading

Table des Matières