7. Programming
PREPARATION
1
The lever releasing the carriage is set in the horizontal position, move the door manually
2
Turn on the power, the lamp lights up when the display shows a value from '99' to '11'
3
The display shows the standby position '- -'
SETTING THE OPENING AND CLOSING POSITION
1
Press and hold the "P" button, until 'P1' is displayed
2
Press the "P' button again, 'OP' will be displayed
3
Press and hold down the "∆" button, during opening process 'OP' flashes
4
Release the "∆" button when the opened position is reached
5
Use "∆" and " " buttons to adjust the opening position
6
Press 'P", 'CL' will be displayed
7
Press and hold down the " " button, during opening process 'CL' flashes
8
Use "∆" and " " buttons to adjust the closing position
9
Press "P", the door will open and close automatically to establish the required normal mechanical force. '- -' will be displayed at the end
ADDING REMOTE CONTROLS.
1
Please press the "C" button, 'Su' will be displayed.
2
Select and press the button on the remote control.
3
Press the same button again to confirm. 'SU' will start flashing, and then you will see '- -'.
Repeat the above steps to add additional eKey remote controls. The memory may store the maximum of 20 remote controls.
4
An attempt to add another remote control will result in displaying 'FU'
DELETING REMOTE CONTROLS
1
Note: This feature will delete all remote controls
2
Press and hold the "C" button for 8 seconds. 'dL' will be displayed.
ADJUSTING THE MECHANICAL FORCE
1
Press and hold the "P" button, until 'P1' is displayed
2
Press the "∆" button once. 'P2' will be displayed
Press "P" again. The current force settings will be displayed. Simultaneously, press "∆" or " " to increase or decrease the force value by one step.
3
The maximum value is 'F9', while the minimum is 'F1'. Press P to confirm.
4
The default settings is 'F3'
PHOTOCELL ACTIVATION AND DEACTIVATION
1
Press and hold the P button until 'P1' is displayed
2
Press the "∆" button twice. 'P3' will be displayed
3
Press the "P" button to see to the status of the photocell. 'H0' means that it is OFF , 'H1' means that is ON
4
Press the "∆" button to activate. 'H1' will be displayed.
5
Press the " " button to inactivate. 'H0' will be displayed.
6
Press P button to confirm and exit.
Note: If the photocells are not installed, make sure that the above-mentioned function is disabled.
7
Otherwise, the operating mechanism will open, but it will not close.
AUTOMATIC CLOSING
1
Press and hold the P button until 'P1' is displayed
2
Press the "∆" button three times. 'P4' will be displayed
3
Press the "P" button to display the status of the automatic closing. 'b0' means no automatic shutdown, while 'b9' means the maximum closing.
4
Press the "∆" button to increase or " " to decrease the delay by one minute.
5
Press P button to confirm and exit.
LOCKING THE REMOTE CONTROL
1
Press and hold the P button until 'P1' is displayed
2
Press the "∆" button four times. 'P5' will be displayed
3
Press "P" again. The current setting will be displayed: 'uL' - no lock of the remote control.
4
Press the "∆" button once. 'Lc' will be displayed - indicating the activation of the lock of the remote control.
5
Press P button to confirm and exit.
VENTILATION - AIRING
1
Press and hold the P button until 'P1' is displayed.
Press the ∆ button five times. 'P6' will be displayed.
2
Press the P button again. The current setting 'r0' will be displayed - ventilation not active. Press the ∆ and
3
to increase or to decrease this value by one level. The maximum value is 'r9'; the minimum value is 'r0'. Press P to confirm.
4
Enable the ventilation option by pressing the CH1 and CH2 buttons simultaneously
OUTDOOR LIGHTING TIME SETTINGS
1
Press and hold the P button until 'P1' is displayed
2
Press the ∆ button six times. 'P7' will be displayed
Press P again. The current setting 'L0' will be displayed - external lighting timeswitch is not active.
3
The maximum value is 'L4'; the value changes by 30 seconds
4
Press P to confirm.
Opening the garage door
uL – opening of the door by pressing a pre-programmed button in the appropriate channel.
Lc – opening of the door by pressing a button with the padlock symbol
Closing the garage door
uL/Lc – pressing a pre-programmed button in the appropriate channel.
Cautions and Warnings
Operate the garage door only when you see everything within its moving range. Do not allow children to play with control mechanisms. Make sure that people are not within the range
of moving garage door. The same applies to animals or objects. The drive is designed for indoor installation and operation. The garage door and the control mechanism should be serviced
every year. Restoring the factory settings of the mechanical force involves steps described in sec. 24-26
34
EN
and then a pre-programmed button in the appropriate channel.
1x
2x
1x
s buttons simultaneously
2x PIN +
← CH1 / 2x PIN +
← CH2
6x
CH1
CH2
CH3
99 - 11
––
P1
OP
OP
CL
CL
––
Su
SU
dL
P1
P2
F3
P1
P3
H0 - H1
H1
H0
P1
P4
b0 - b9
P1
P5
uL
Lc
r0 - r9
P1
P7
L0 - L4
6x