ELEC
INDICATION SYSTEM
ON
Max. 2.5 mm
(0.010 in.)
OF
F
OIL LEVEL SENSOR
1. Meadure:
S Oil level sensor continuity Out of specifica-
tion ! Replace.
Float position
OFF
ON
Float length a :
37,0 X 41,0 mm (1,46 X 1,61 in)
OIL LEVEL WARNING LAMP
1. Check:
S Display function Not working ! Replace.
Checking steps:
S Connect the battery.
Voltage range:
10 X 16 V
1 Red lead ! Positive terminal.
2 Green lead ! Positive terminal.
3 Black lead ! Negative terminal.
S After connecting the battery, oil, warning
LED starts to lighy up for 3 seconds and
then blinks.
S Connect the jumper lead a to the blue and
black terminals to check the oil warning
LED goes off, after blinking for 10 – 30 se-
conds.
50
Checing leads
L
B