Hilti TE 1000-AVR 02 Mode D'emploi Original page 13

Burineur
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Trouble or fault
The service indicator blinks
red.
No hammering action.
The tool does not achieve full
power.
The chisel cannot be released
from the chuck.
The power tool switches itself
off while running.
9 Disposal
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative
for further information.
▶ Disposal of electric tools or appliances together with household waste is not permissible.
10 China RoHS (guideline on restriction of the use of dangerous substances)
The following link takes you to the table of dangerous substances: qr.hilti.com/r1905292.
You will find a link to the RoHS table, in the form of a QR code, at the end of this document.
11 Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
Printed: 07.06.2017 | Doc-Nr: PUB / 5165616 / 000 / 05
Possible cause
The voltage provided by the elec-
tric supply is too high.
The overheating prevention cut-out
has been activated.
The power tool is too cold.
Power reduction is active.
The extension cord is too long or
its gauge is inadequate.
The voltage provided by the elec-
tric supply is too low.
The chuck is not pulled back fully.
The overheating prevention cut-out
has been activated.
Action to be taken
▶ Use a different power outlet.
Check the electric supply.
▶ Allow the tool to cool down.
Clean the air vents. Running
under no load is still possible.
▶ Bring the tip of the accessory
tool into contact with the
working surface, switch the
power tool on and allow it to
run. If necessary, repeat the
procedure until the hammering
mechanism begins to operate.
▶ Press the power level selector
switch (observe the power level
indicator). Unplug the power
tool from the electric supply and
then plug it back in.
▶ Use an extension cord of an
approved length and / or of
adequate gauge.
▶ Connect the power tool to a
different power source.
▶ Pull the chuck back as far as
it will go and remove the insert
tool.
▶ Allow the tool to cool down.
Clean the air vents. Running
under no load is still possible.
English
9

Publicité

Table des Matières
loading

Table des Matières