Fitting the Chimney and Fixing the Hood Canopy
• Insert the Top chimney with the slots facing upwards when
installing the recirculation version, or vice versa with the slots
facing downwards when installing the ducting version, then fix
the top part to the Upper Chimney Connector using the screws
12c (2.9 x 9.5) provided.
Recirculation version
• Make sure that the Air Outlet Connector 15 is positioned in
correspondence with the Chimney Grill.
• If this is not the case, remove the chimney and adjust the posi-
tion of the Air Outlet Connector 15; replace the components as
described above.
Before fixing the Hood Canopy to the Frame:
• Remove the metal grease filters from the hood canopy.
• Remove any activated charcoal odour filters.
• Fix the hood canopy to the frame provided, working from be-
low and using the 4 screws 12f supplied.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.
• Join the connectors.
• Install the odour filter and the charcoal filter in case the hood is
to be used in recycling version.
• Install the grease filter again.
EN
12f
12c
1
13
3