Electrical Outlet

The electrical requirements are a 120 volt 60 Hz, AC
only, 15 amp. or more protected electrical supply. It is
recommended that a separate circuit serving only this
appliance be provided.
The drawer is equipped with a 3-prong grounding plug.
It must be plugged into a wall receptacle that is properly
installed and grounded. Should you only have a 2-prong
outlet, have a qualified electrician install a correct wall
receptacle.
Note: If you have any questions about the grounding or
electrical instructions, consult a qualified electrician or
service technician.
* Can also be installed using an electrical outlet in an
adjacent cabinet within the area where the provided
electrical cord can reach.
Always check electrical codes for requirements.

Grounding Instructions

This appliance must be grounded. The Drawer Microwave
is equipped with a cord having a grounding wire with a
grounding plug. It must be plugged into a wall receptacle
that is properly installed and grounded in accordance
with the National Electrical Code and local codes and
ordinances. In the event of an electrical short circuit,
grounding reduces risk of electric shock by providing an
escape wire for the electric current.
WARNING – Improper use of the grounding plug can result
in a risk of electric shock. Do not use an extension cord. If the
power supply cord is too short, have a qualified electrician
or serviceman install an outlet near the appliance.
3-Prong plug
Grounding pin
3-Prong receptacle
Grounded receptacle box
6
Figure 10
Grounded receptacle box
Grounding adapter
Screw
Tab for grounding screw

Standard Mount Drawer Installation

1. Place the drawer adjacent to the wall or cabinet opening.
Plug the power supply cord into the electrical outlet.
2. Carefully guide the drawer into the prepared opening.
Avoid pinching the cord between the oven and the wall.
3. Slide the drawer all the way until the mounting flange is
flush with the face of the cabinet. See Figure11.
4. Open the drawer. Using the 4 holes on the drawer as
a template, pre-drill the cabinet using a
Figure 11.
5. Secure the drawer with the 6 screws supplied.
Figure 11

Flush Mount Drawer Installation

1. Prepare cabinet opening as shown in Figures 5, 6, 7.
2. Install deflector as shown in Figure 8A.
3. Place the drawer adjacent to the wall or cabinet opening.
Plug the power supply cord into the electrical outlet.
4. Carefully guide the drawer into the prepared opening.
Avoid contact with the sides of the cutout opening and
also pinching the cord between the oven and the wall.
5. Slide the drawer all the way back until the mounting
flanges touch the cleats mounted in the cabinet opening.
6. Open the drawer. Using the 4 holes on the drawer as a
template, pre drill the cabinet using a
bit. See Figure 11.
1
" bit. See
16
Mounting Screws
1
/
" (1.57 mm)
16