• The microwave interior will easily accommodate a
9" x 13" oblong dish or a bag of microwave popcorn.
• The oven can also be mounted flush. Please see
instructions for flush m ounting.
Standard Mount and Measurements
A 6" (152.4 mm)
B Suggested electrical outlet location*
C Anti-Tip block
D 5" (127 mm)
E 3
1
" (89 mm)
2
F 4" (101.6 mm)
G 22
1
" (562 mm) opening
8
H 14
13
" (376.3 mm) to bottom of Anti-Tip block
16
Allow
7
" (22.2 mm) overlap
I
8
23
1
" (597 mm) minimum depth
J
2
3
K Allow
" (4.76 mm) overlap
16
L 36" (914.4 mm) countertop height
1
M Allow
" (3.18 mm) minimum space
8
N Floor must support 100 lb (45 kg)
O 24" (610 mm) cabinet minimum
P 15
9
" (395.3 mm) opening
16
B
D
M
F
G
I
J
L
O
Figure 1
A
C
E
H
K
P
I
N
Installation Guide
A 21
5
" (549.3 mm)
8
B 4
11
" (119 mm)
16
C 1
3
" (44.5 mm)
4
D 21
7
" (555.6 mm)
8
23
7
" (606.43 mm)
8
E
15
7
" (403.22 mm)
8
F
G 14
19
" (370.69 mm)
32
H 1
9
" (29 mm) door thickness
64
15" (381 mm) auto drawer opening
I
4" (101.6 mm)
J
B
C
J
F
E
Figure 2
Figures 1 and 2 contain measurements for reference when
B
planning the drawer's location.
This Drawer Microwave can be installed below any electric
or gas wall oven.
* Can also be installed using an electrical outlet in an
E
adjacent cabinet within the area where the provided
C
electrical cord can reach. Power cord access hole in
cabinet should be a minimum 1
hole and deburred of all sharp edges.
D
IMPORTANT Always allow sufficient power cord length to
the electrical outlet to prevent tension.
Always check electrical codes for requirements.
EN
A
G
I
D
H
A
1
" (38 mm) diameter
2
G
F
3

Publicité