Gallagher 3E4451 M1100 M1500 Energizer User Manual
TROUBLESHOOTING
Problem
Energizer has started to
run slowly
Energizer doesn't
operate
Electric fence voltage
is below 3000V or your
stock are escaping
Save these instruc ons.
Causes
The internal temperature of
the energizer is too high
Energizer Off
Break in supply circuit
Faulty energizer
Faulty energizer
Inadequate earthing
Short on the fence line
Solu on
Mount the energizer in a cool
area, out of direct sun and with
adequate ven la on.
Switch ON
Test power point
Have energizer repaired
Unplug the energizer from
the power supply and remove
the fence wire from the Red
terminal. Plug energizer in
again. Using a Digital Volt Meter
(G503) check the voltage across
the terminals. If the voltage is
less than 5000V, have energizer
repaired.
Improve the earth system by
adding more galvanised earth
stakes to the earth system un l
the earth voltage is 200V or
below.
Check the electrical connec ons
are secure eg. from the fence to
the red terminal, from the earth
system to the green terminal,
at gates etc. Check the voltage
on the fence every 33m (100 )
using the Digital Volt Meter. Note
if the voltage is dropping. The
closer to a fault, the lower the
voltage reading will be. Become
aware of things that cause faults
and always be on the lookout
for: stray pieces of wire on the
fence, heavy vegeta on growth,
cracked or broken insulators,
broken wires.
13