Troubleshooting - Oreck ProShield Guide D'utilisation

Épurateur d'air
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Trouble-
shooting
Problem
Unit does not
turn ON.
Truman Cell
®
light has turned
solid red.
Truman Cell
®
light is
blinking red.
Unit does
not reduce
particles.
Unit sparks,
crackles and
pops.
Unit still does
not operate
properly.
Service problems that appear to be major can often be solved
easily. You can be your own troubleshooter by reviewing this guide.
All other servicing should be done by an Oreck authorized
service center.
Check
• Power Cord
• Selector Switch
• Top Cover
• ALCI Plug
Truman Cell
®
Truman Cell
®
Truman Cell
®
Truman Cell
®
Review all the
above.
11
• Plug in Power Cord
• Set Selector Switch for desired blower
speed.
• Make sure the top cover is securely closed
• Press the red reset button each time you
plug in the ALCI safety device.
• A solid red light is a 30 day cleaning
reminder. Wash Truman Cell
it is thoroughly clean before reinstalling.
• A fast blinking light indicates the power
supply has shut down due to arcing or
short circuit. The cell should be inspected
and cleaned, repaired, or replaced.
• A slow blinking light indicates the unit is
in Dry Mode.
• Clean the Truman Cell
• Truman Cell
may be damaged. Contact
®
Oreck for service.
• Sparking or popping noise (arcing) can
occur when a large particle is captured
in the Truman Cell
excessively, the cell may be dirty. Try
cleaning the Truman Cell
• If excessive arcing continues after proper
cleaning, the Truman Cell
damaged. If damaged, contact Oreck for
service.
Contact Oreck for service.
Solution
. Make sure
®
.
®
. If the unit is arcing
®
.
®
may be
®