EN
STATUS FOLDER
All information on these pages is read only�� Page numbers are valid
for when the password is entered�� When the password is not entered
the pages may be arranged slightly differently��
Page 1– Analog Inputs
Figure 49 : Analog Inputs
Analog Inputs:
The following analog inputs are displayed in this section.
•
Package Discharge Pressure – The pressure the compressor is delivering
to the plant
•
Airend Discharge Temperature – The temperature of the air/oil mixture
at the discharge of the compression module.
•
Pages 2 Thru 4 – Compressor Data
Figure 50 : Compressor Data
Compressor Data:
Power oN Hours – Number of hours that the controller has been
•
powered up
•
Running Hours – Number of hours the compressor's motor has been
running
•
Motor Speed – Current speed of the motor in RPM
Time – Current time of day.
•
EN-26
RELEASED 16/Dec/2014 10:49:53 GMT
NOTICE
•
Motor Current – Electrical current currently being drawn by the motor.
Motor Voltage – Electrical voltage at the motor.
•
•
DC Link Voltage – DC Bus Voltage on the VSD
Package kW – Instantaneous power consumption of the compressor
•
•
Heatsink Temperature – Temperature of the VSD at the heatsink
Control Card Temperature – Temperature of the VSD at the control card
•
•
Pages 5 & 6 – Digital Inputs
Figure 51 : Digital Inputs
Digital Inputs: (Password Required)
Each digital input will have an indication showing whether the input is in
an "OPEN" or "CLOSED" state. This is the physical state of the input and may
not necessarily line up with the logical condition. The normal state is shown
below.
•
Emergency Stop – Normally Closed
•
Main/Fan Motor overload – Normally Closed
•
Remote Start - Normally Open
•
Remote Stop – Normally Closed
•
Dryer Temperature Fault – Normally Open
•
Dryer High Pressure – Normally Closed
80448483 Rev.B