INSTALLING THE WALL NICHE IN CONCRETE SHUTTERED POOLS
Installation (picture number 1a ABS version)
Position first stage wall and wall components flush with structural concrete.
Remove protective covers only when ready to lay tiles / mosaics. In the case of a concrete/liner pool first stage components may
project in order to compensate for cement render or liner insulation thickness. Locate the pneumatic switch housing in a conveni-
ent position 15-20 cm below water level. It is advisable to make provision for protecting the pneumatic tube (PVC 2/4 dia.) and air
inlet tubes (PVC 12/21 dia.) by placing in protective conduit or through adjacent cable/ventilation ducts.
Tile plan (picture number 2a and 3a ABS version)
Render and tile to inner edge. Render & tile 6 cm max.
Pools with plastic liner (picture number 5 red bronze version, picture number 5a ABS version)
Steel, aluminum and polyester pools (picture number 5 red bronze version, picture number 5a ABS version)
Pneumatic switch (picture number 6 red bronze version and ABS version)
1a
Concrete
Pneumatic
switch
housing
Shuttering
screws
M 6x35 if required
24
dimensions in cm
Shuttering
24
Sticker „top"
Ø17
Air net tube 8 m long
Instal floor fitting
flush with floor
Protective sleeve for
pneumatic tube Wall
thickness 24 -100 cm
24
approx 5-10 cm
above waterlevel
Wall fitting
for suction
unit
Stopper 2"
2" PVC/ABS tube, elbow
Supplied by pool builder
14
2a
Render & tile
to inner edge
Render & tile
6 cm max.
3a
6 cm

Publicité