Led-Signals; Technical Specifications - GEZE GC 334 Manuel D'utilisation

Masquer les pouces Voir aussi pour GC 334:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5

LED-SIGNALS

The RED or GREEN
Bad calibration
LED is ON sporadicly
or permanently.
Bad adjustment of the
uncovered zone.
The sensor is disturbed by
lamps or another sensor.
The sensor does not
The monitoring is activated,
react, but a calibration
but the test input is not
can be launched.
powered.
The sensor encounters a
The ORANGE LED is
memory problem.
on permanently.
The ORANGE LED
DIP-switch setting
fl ashes quickly.
awaiting confi rmation.
The sensor signals an
The ORANGE LED
internal fault.
fl ashes 1 x
1
every 3 seconds.
The ORANGE LED
Power supply is out of limit.
fl ashes 2 x
2
every 3 seconds.
Communication error
The ORANGE LED
between modules.
fl ashes 3 x
3
every 3 seconds.
The sensor receives
The ORANGE LED
not enough IR-energy.
4
fl ashes 4 x
every 3 seconds.
The ORANGE LED
Calibration error
fl ashes 5 x
5
every 3 seconds.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of the sensor.
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance
with applicable national and international regulations and standards on door safety.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
- Only trained and qualifi ed personnel may install and setup the sensor.
- The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel.
GEZE GmbH / Reinhold-Vöster-Straße 21-29 / 71229 Leonberg / Germany / Tel. ++49(0)7152-203-0 / Fax ++49(0)7152-203-310
GEZE hereby declares that the GC 334 is in conformity with the basic requirements and the other relevant provisions of the directives
2014/30/EU, 2006/42/EC and 2011/65/EU.
Notifi ed Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certifi cate number: 44 205 12 405038
Leonberg, June 2016
Hermann Alber, Authorized representative and responsible for technical documentation
The complete declaration of conformity is available on our website: www.geze.com
Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)
Mat.-Nr. 126833
Änd.-St. 03
Zeichn.-Nr. 70710-9-9508
1
Launch a calibration.
1
Check if the DIP-switch 4 is in correct position.
2
Launch a calibration.
1
Select a different frequency for each module (DIP 2).
Launch a calibration.
2
Chech wiring.
1
- Door control with test:
Connect RED and BLUE wires to test output.
- Door control without test:
Connect BLUE to 0 V and RED to +12 V - 30 V DC.
1
Send the sensor back for a technical check-up.
Corfi rm the DIP-switch setting:
1
long push on the push button.
1
Cut and restore power supply.
2
If orange LED fl ashes again, replace sensor.
1
Check power supply (tension, capacity).
2
Reduce the cable length or change cable.
Check wiring between modules.
1
Launch a module count: long push on push button
2
of MASTER.
1
Launch a new calibration and step out of
the detection fi eld.
2
Change angle of spots.
3
Switch off background (DIP 3: OFF).
1
Check mounting height.
2
Change position of calibration screw.
3
Launch a new calibration.
4
Switch off background (DIP3: OFF)
Printed in Germany
Änderungen vorbehalten
PLEASE KEEP FOR FURTHER USE
DESIGNED FOR COLOUR PRINTING
DRAFT
DESCRIPTION
1
2
3
4
5
6
1.
2.
3.
4.
5.
6.

TECHNICAL SPECIFICATIONS

Technology:
active infrared with background suppression
Detection fi eld:
400 mm (W) x 70 mm (D) (at 2 m mounting height; 4 spots active)
Mounting height:
1.3 m to 3.5 m
Reaction time:
64 ms (typ)
Max. presence time:
infi nite
Supply voltage:
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
(to be operated from SELV compatible power supplies only)
Max current consumption:
95 mA @ 24 V AC/ 70 mA @ 24 V DC; 170 mA @ 12 V AC/ 130 mA @ 12 V DC (MASTER)
85 mA @ 24 V AC/ 60 mA @ 24 V DC; 180 mA @ 12 V AC/ 113 mA @ 12 V DC (other modules)
Output:
2 relays (free of potential contact)
Max. contact voltage
42 V AC/DC
Max. contact current
1 A (resistive)
Max. switching power
30 W (DC) / 42 VA (AC)
Input:
1 optocoupler (free of potential contact)
Max. contact voltage:
30 V
Voltage threshold:
high: >10 V DC; low: <1 V DC
Max. number of modules:
4 (up to 6 if 24 V DC)
Refl ectivity:
min. 5% at IR-wavelength of 850 nm
Degree of protection:
IP53
Temperature range:
-25 °C to +55 °C; 0-95% relative humidity, non condensing
Expected lifetime:
20 years
Norm conformity:
DIN 18650-1 ch. 5.7.4; BS 7036-2*; EN 16005 ch. 4.6.8;
EN 12978; EN 61508; IEC 61496-2; BGR 232;
EN ISO 13849-1 Performance Level «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
* max. mounting height for BS 7036-conformity (UK): 3.25 m
Safety sensor
for automatic swing doors
User's Guide for product version 0500 and higher
See product label for serial number
profi le
7.
end cap
supporting clip
8.
clip with angle adjustment screw
main connector
9.
transmitter (TX)
DIP-switch
10.
push button
calibration screw
11.
front face
receiver
Specifi cations are subject to changes without prior notice.
All values measured in specifi c conditions.
7
8
9
10
11

Publicité

Table des Matières
loading

Table des Matières