Samlex Europe Pure Sinewave PST-300S-12E Mode D'emploi page 5

Table des Matières

Publicité

SECTION 1 |
!
CAUTION!
To prevent possibility of paralleling and severe damage to the unit, never use a
simple jumper cable with a male plug on both ends to connect the AC output
of the unit to a handy wall receptacle in the home / RV.
Preventing DC Input Over Voltage
It is to be ensured that the DC input voltage of this unit does not exceed 16.5 VDC for
the 12V battery version and 33.0 VDC for the 24V battery version to prevent permanent
damage to the unit. Please observe the following precautions:
• Ensure that the maximum charging voltage of the external battery charger / alterna-
tor / solar charge controller does not exceed 16.5 VDC for the 12V battery version and
33.0 VDC for the 24V battery version
• Do not use unregulated solar panels to charge the battery connected to this unit.
Under cold ambient temperatures, the output of the solar panel may reach > 22 VDC
for 12V Battery System and > 44 VDC for the 24V Battery system. Always use a charge
controller between the solar panel and the battery.
• Do not connect this unit to a battery system with a voltage higher than the rated bat-
tery input voltage of the unit (e.g. do not connect the 12V version of the unit to 24V
battery system or the 24V version to the 48V Battery System)
Preventing Reverse Polarity on the Input Side
When making battery connections on the input side, make sure that the polarity of bat-
tery connections is correct (Connect the Positive of the battery to the Positive terminal
of the unit and the Negative of the battery to the Negative terminal of the unit). If the
input is connected in reverse polarity, DC fuse(s) inside the inverter will blow and may
also cause permanent damage to the inverter.
!
CAUTION!
Damage caused by reverse polarity is not covered by warranty.
Use of External Fuse in DC Input Circuit
Use Class-T or equivalent fuse of appropriate capacity within 20 cm of the battery Positive ter-
minal. This fuse is required to protect DC input cable run from damage due to short circuit
along the length of the cable. Please read instructions under Section 7 - Installation.
Hard Wiring of AC Output to AC Panelboards in RVs / Motor Homes / Trailers /Campers/Van's
WARNING!
RISK OF ELECTRIC SHOCK
When this unit is installed in RV / Motor Homes / Trailers / Campers / Van's and hard-
wiring connection is used to feed the AC output of the inverter to the AC Distri-
bution Panelboard / Load Center in the vehicle, it is to be ensured that Ground
f ault Circuit Interrupter(s) [Gf CI]are installed in the vehicle wiring system to
protect branch circuits.
Safety Instructions
SAMLEX AMERICA INC. | 5
5
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pure sinewave pst-300s-24e

Table des Matières