1
2
1
Slip the conduit adapter
cable.
3
Slip the clamping device onto the connection cable.
Screw the coupling (A) of the conduit adapter into
the clamping device.
5
Push the clamp fastener
sensor.
3
4
5
6
⑦
onto the connection
A
①
from above onto the
①
clamp fastener
7
②
sensor
③
connection cable
④
seal
⑤
clamping device
⑥
nuts
⑦
conduit adapter
with ½"-14 NP coupling
2
Remove the protective foil from the seal
Glue the seal onto the clamping device
4
Screw the connection cable onto the sensor plug.
6
Screw the clamping device slightly onto the clamp
fastener. Align the adapter and tighten the screws
evenly (max. tightening torque 5 Nm /3.5 Lbf.ft).
④.
⑤.
3