INTERFACING FOR LOCK STATUS

OUT1 and OUT2 outputs can be used to remotely control lock status.
OUT1 output is activated when the lock is securely locked (latchbolt and deadbolts engaged).
OUT2 output is activated when the lock is completely open (latchbolt and deadbolts withdrawn).
EN
N.B.: Both the outputs are free contacts normally open (FC NO) with a maximum capacity
of 60V, 0.5mA
Connect devices with a maximum current absorption of 0.5A and a maximum
voltage of 60V. CISA declines all responsibility for the compliance of third-party
devices used
FR
It is possible to connect the 12V DC lights (see the accessories) directly to the lock power
supply. Respect the polarity (+/-) of the lights/LEDs
A repeater relay (item 1.07022.20.0) is needed to control locks, electric strike coils or 230V
devices.
ES
12V DC
24W
DE
GR
RU
PL
+
-
Red | V+ | Power supply (+)
Black | V- | Power supply (-)
Orange | OUT1/C | Securely locked lock status
Orange/white | OUT1/NO | Securely locked lock status
Brown | OUT2/C | Open lock status
Brown/white | OUT2/NO | Open lock status
OUT1
OUT2
+
DOOR STATUS
+
DOOR STATUS
- 30 -
-
Max
CLOSE
60V - 0.5A
-
Max
OPEN
60V - 0.5A