5 Specifications, 75V models
SmartSolar charge controller
Battery voltage
Maximum battery current
Nominal PV power, 12V 1a,b)
Nominal PV power, 24V 1a,b)
Max. PV short circuit current 2)
Automatic load disconnect
Maximum PV open circuit voltage
Peak efficiency
Self consumption
Charge voltage 'absorption'
Charge voltage 'equalization'
Charge voltage 'float'
Charge algorithm
Temperature compensation
Continuous load current
Low voltage load disconnect
Low voltage load reconnect
Protection
Operating temperature
Humidity
Maximum altitude
Environmental condition
Pollution degree
Data communication
Colour
Power terminals
Protection category
Weight
Dimensions (h x w x d)
Safety
1a) If more PV power is connected, the controller will limit input power
1b) The PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1V.
2) A higher short circuit current may damage the controller in case of reverse polarity connection of the PV
array.
10
MPPT 75/10
12/24V Auto Select
10A
145W
290W
13A
Yes, maximum load 15A
14,4V / 28,8V
16,2V / 32,4V
13,8V / 27,6V
multi-stage adaptive or user defined algrithm
-16mV / °C resp. -32mV / °C
11,1V / 22,2V or 11,8V / 23,6V
or BatteryLife algorithm
13,1V / 26,2V or 14V / 28V
or BatteryLife algorithm
Battery reverse polarity (fuse)
Output short circuit / Over temperature
-30 to +60°C (full rated output up to 40°C)
100%, non-condensing
5000m (full rated output up to 2000m)
Indoor type 1, unconditioned
VE.Direct port or Bluetooth
See the data communication white paper on our website
ENCLOSURE
Blue (RAL 5012)
6mm² / AWG10
IP43 (electronic components)
IP22 (connection area)
100 x 113 x 40mm
STANDARDS
EN/IEC 62109-1, UL 1741, CSA C22.2
MPPT 75/15
15A
220W
440W
15A
75V
98%
10mA
(adjustable)
(adjustable)
(adjustable)
15A
PD3
0,5kg