Dip Switch
Function
Dip 1 = OFF
Infrared sensor sensitive area up to 6 m
Dip 2 = OFF
Dip 1 = ON
Infrared sensor sensitive area up to 8 m
Dip 2 = OFF
Dip 1 = OFF
Infrared sensor sensitive area up to 10 m
Dip 2 = ON
Dip 1 = ON
Infrared sensor sensitive area up to 12 m
Dip 2 = ON
Dip 3 = OFF
N° infrared pulses for alarm = 1
Dip 3 = ON
N° infrared pulses for alarm = 2
Dip 4 = OFF
Signalling leds active
Dip 4 = ON
Signalling leds off
Dip 5 = OFF
Rear tamper protection active
Dip 5 = ON
Rear tamper protection deactivated
Dip 6 = OFF
Temperature compensation deactivated
Dip 6 = ON
Temperature compensation activated
Table 1
Notes
5
4
3
2
1
1
m
0
1
2
3
4
5
Caution! – Led signalling increases battery
consumption. In the "Test" phase, the leds are active.
Deactivate if not required or when the rear tamper
protection cannot be used.
It automatically increases sensitivity of the PIR when the
ambient temperature exceeds 30°C. Do not activate this
function unless absolutely necessary.
m
2
3
4
5
6
7
8
9
10
11
12
English - 3