Output
Table 2
kW (240V)
DROP 4.5
DROP 6
DROP 7.5
DROP 9
Output
Table 3
kW (208V)
DROP 4.5
DROP 6
DROP 7.5
DROP 9
NB!
It is forbidden to use a non-heat-resistant cable with PVC isolation
as the power cable. The joint box must be waterproof and it must be
located up to 19.7 in (50 cm) from the floor.
•
Open the cover of the heater's electrical box.
•
Attach the power cable on the terminal block according to the
circuit diagram.
•
Close the cover.
•
Fix the cable on the output with a cable strap.
•
Install the heater on the wall frame.
6
Room
106-247 ft
4.5
3–7 m
177-353 ft
6
5–10 m
247-424 ft
7.5
7–12 m
282-530 ft
9
8–15 m
Room
88-194 ft
3.4
2.5-5.5 m
141-282 ft
4.5
4-8 m
176-318 ft
5.6
5-9 m
211-388 ft
6.75
6-11 m
Amps
Circuit Breaker
A
3
18.75
3
3
25
3
3
31.25
3
3
37.5
3
Amps
Circuit Breaker
A
3
16.35
3
3
21.63
3
3
26.92
3
3
32.45
3
Wire Size
A
AWG
30
10
30
10
40
8
50
8
Wire Size
A
AWG
20
12
30
10
30
10
40
8