HUUM DROP Manuel D'installation Et D'opération page 6

Masquer les pouces Voir aussi pour DROP:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Output
Table 2
kW (240V)
DROP 4.5
DROP 6
DROP 7.5
DROP 9
Output
Table 3
kW (208V)
DROP 4.5
DROP 6
DROP 7.5
DROP 9
NB!
It is forbidden to use a non-heat-resistant cable with PVC isolation
as the power cable. The joint box must be waterproof and it must be
located up to 19.7 in (50 cm) from the floor.
Open the cover of the heater's electrical box.
Attach the power cable on the terminal block according to the
circuit diagram.
Close the cover.
Fix the cable on the output with a cable strap.
Install the heater on the wall frame.
6
Room
106-247 ft
4.5
3–7 m
177-353 ft
6
5–10 m
247-424 ft
7.5
7–12 m
282-530 ft
9
8–15 m
Room
88-194 ft
3.4
2.5-5.5 m
141-282 ft
4.5
4-8 m
176-318 ft
5.6
5-9 m
211-388 ft
6.75
6-11 m
Amps
Circuit Breaker
A
3
18.75
3
3
25
3
3
31.25
3
3
37.5
3
Amps
Circuit Breaker
A
3
16.35
3
3
21.63
3
3
26.92
3
3
32.45
3
Wire Size
A
AWG
30
10
30
10
40
8
50
8
Wire Size
A
AWG
20
12
30
10
30
10
40
8