Recommendations - ELRO PRECIJET+ 6 GN1/1 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3E-490044NU – 03/20
These appliances are for professional use, only appropriately trained personnel should use them.
These appliances are intended to be used for commercial applications, for example in kitchens of restaurants, canteens, hospitals and in
commercial enterprises such as bakeries, butcheries, etc., but not for continuous mass production of food.
These appliances must be installed with sufficient ventilation to prevent the formation of an excessive concentration of substances harmful for
health within the premises in which they are installed.
The rate of new air required for combustion is 2m3/h per kW of heating power.
Never block the condensate exhaust flue, because the pressure could rise in the appliance and pose a risk of explosion.
If an error message appears consult the list of error messages and follow the ADVICE given
When cleaning high pressure jets or lances should never be used.
NEVER start the oven WITHOUT HAVING POSITIONED AND LOCKED the ventilation duct.
Do not remove the ventilation duct and the drain grid located in the oven. If this grid is missing do not start the oven.
Always use a qualified technician to install the equipment and if necessary change the oven from one gas to another.
IMPORTANT: Please be aware that when cooking dishes prepared with alcohol (coq au vin, pears in wine, etc....). Vapour saturated with
alcohol may when heated cause an explosion in the oven and due to the sealed door, create a momentary overpressure which may cause an
irreversible deformation of the panels. This risk is further increased when the user adds alcohol to the products near the end of the cooking cycle
and closes the door to complete cooking.
The appliance must be isolated electrically during cleaning or maintenance and when replacing parts.
For long term reliability and safety it is advisable to have the unit serviced by suitably qualified technicians
inspection and cleaning of venturis, cleaning jets, adjustment of air rings, cleaning vents, checking for possible leaks, checking control elements,
regulating and safety accessories...).
The oven must be meticulously maintained on a DAILY basis (see the "Maintenance" chapter). In particular, the fans, heating elements
and internal surfaces must be kept clean grease and mineral deposits must not be allowed to accumulate.
Preheating (20 level ovens): Whatever the cooking mode, these ovens are designed to be preheated with the trolley in place. See «practical use
advice ».
Using a trolley or preheating plate (optional) is compulsory for automatic cleaning of 20 level ovens.
Never place the probe behind the ventilation duct (the probe may deteriorate in proximity to the elements or gas exchange.
NEVER APPLY ANY CLEANING PRODUCT WHEN THE OVEN IS HOT, AT ANYTHING OVER 60°C THE SURFACE WILL BE
IRREPARABLY DAMAGED.
Do not open the oven door during a cleaning cycle.
Combination ovens should be cleaned with specific products which can resist temperature of up to 70°C. An inappropriate cleaning or descaling
product may have a slightly corrosive effect.
The detergent chemical risk should not exceed 3 in accordance with EN 1717 (Toxicological information FDS: LD50 > 200mg/kg).
We strongly recommend the use of cleaning products supplied by the manufacturer to ensure good results and optimize the service
life of its components.
Except for the UK market: No detergent product is recommended or supplied. Any detergent used with this appliance must have been verified to
represent no greater risk than Fluid Category 3. If the detergent used represents a Fluid Category risk greater than Fluid Category 3 alternative
backflow protection to the double check valve supplied with the appliance will be required immediately upstream of the appliance. The backflow
protection used must be appropriate to the risk posed by the detergent.
For maximum efficiency of the descaling product without damaging the material and components of the oven, you should use an appropriate
descaler. It must also comply with legal requirements, in particular for material intended to come into contact with foodstuffs.
Chemical products containing nitric acid are strictly prohibited. Recommended composition:
- Phosphoric acid <50%
- Corrosion inhibitor
The automatic cleaning system is exclusively designed to achieve an introduction of cleaning and degreasing chemical. Never use a descaling
agent. This would damage the hydraulic system of the oven irreversibly.
Under no circumstances should the oven be cleaned with grills or containers in situ.
The core probe socket and USB port are fitted with silicone protective covers.
- Always put the protective cover in place (lowered to protect connections) whenever the socket is not in use.
- Never "clean" connections with a water hose or a sponge. (If the silicone cover is used and put back in place after use,
The manufacturer certifies that the packaging meets the provision 94/62/CE (relating to packaging and packaging waste of 20.12.94) and
requests that the final installer (or user) observes the rules relating to the removal of the packaging (recycling or reuse).
« According to article 6 of the decree of 20 July 2005 a marking giving the identity of the manufacturer and the market release date must appear
on equipment after 13 August 2005».
« The Manufacturer has filled in the National Register. »
As per the legal provisions in force (article 21 & 22 of the decree 2005-829), the customer is responsible for the obligations relating to the
elimination of electric and electronic waste, namely:
- he is to deal with selective treatment, reconditioning and destruction of residue arising from electric and electronic equipment, selectively
collected in the installations meeting the technical requirements or in any other installation authorised for the purpose, in another member
State of the European Union, or in another State so far the transfer of these residues out of France is made according to the provisions of
the Regulation of 1st February 1993 indicated above.

21 RECOMMENDATIONS

no maintenance is necessary).
Page 10
Drain grid
EN
(Dismantling of burners,
ELRO-Werke AG
Wohlerstrasse 47
5620 Bremgarten

Publicité

Table des Matières
loading

Table des Matières