In Case Of Failure; Disposing Of The Unit; How To Operate - Mitsubishi Electric P36NMHU-E-OA Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Warning:
Do not splash water over the unit and do not touch the unit with wet
hands. An electric shock may result.
Do not spray combustible gas close to the unit. Fire may result.
Do not place a gas heater or any other open-flame appliance where it will
be exposed to the air discharged from the unit. Incomplete combustion
may result.
Warning:
Do not remove the front panel or the fan guard from the outdoor unit
when it is running. You could be injured if you touch rotating, hot or
highvoltage parts.
Never insert fingers, sticks etc. into the intakes or outlets, otherwise
injury may result, since the fan inside the unit rotates at high speed.
Exercise particular care when children are present.
If you detect odd smells, stop using the unit, turn off the power switch
and consult your dealer. Otherwise, a breakdown, electric shock or fire
may result.
When you notice exceptionally abnormal noise or vibration, stop
operation, turn off the power switch, and contact your dealer.
Do not over-cool. The most suitable inside temperature is one that is
within 5°C [9°F] of the outside temperature.
Do not leave handicapped people or infants sitting or standing in the path
of the airflow from the air-conditioner. This could cause health problems.
Caution:
Do not direct the airflow at plants or caged pets.
Ventilate the room frequently. If the unit is operated continuously in a
closed room for a long period of time, the air will become stale.

2. How to operate

4
3
Function buttons
7
8
not perform its function. (except for the ON/OFF button)
from the Menu screen.
5
6
2
1
9
0

In case of failure

Warning:
Never remodel the air conditioner. Consult your dealer for any repair or
service. Improper repair work can result in water leakage, electric shock,
fire, etc.
If the remote controller displays an error indication, the air conditioner
does not run, or there is any abnormality, stop operation and contact your
dealer. Leaving the unit as it is under such conditions can result in fire or
failure.
If the power breaker is frequently activated, get in touch with your dealer.
Leaving it as it is can result in fire or failure.
If the refrigeration gas blows out or leaks, stop the operation of the air
conditioner, thoroughly ventilate the room, and contact your dealer.
Leaving the unit as it is can result in accidents due to oxygen deficiency.
When the air conditioner is not to be used for a long
time
If the air conditioner is not to be used for a long time due to a seasonal
change, etc., run it for 4 - 5 hours with the air blowing until the inside is
completely dry. Failing to do so can result in the growth of unhygienic,
unhealthy mold in scattered areas throughout the room.
When it is not to be used for an extended time, keep the [power supply]
turned OFF.
If the power supply is kept on, several watts or several tens of watts will
be wasted. Also, the accumulation of dust, etc., can result in fire.
Keep the power switched ON for more than 12 hours before starting
operation. Do not turn the power supply OFF during seasons of heavy
use. Doing so can result in failure.

1.3. Disposing of the unit

Warning:
When you need to dispose of the unit, consult your dealer. If pipes are
removed incorrectly, refrigerant (fluorocarbon gas) may blow out and come
into contact with your skin, causing injury. Releasing refrigerant into the
atmosphere also damages the environment.
1 ON/OFF button
Press to turn ON/OFF the indoor unit.
2 SELECT button
Press to save the setting.
3 RETURN button
Press to return to the previous screen.
4 MENU button
Press to bring up the Main menu.
5 Backlit LCD
Operation settings will appear. When the
backlight is off, pressing any button turns the
backlight on and it will stay lit for a certain
period of time depending on the screen.
6 ON/OFF lamp
This lamp lights up in green while the unit is
in operation. It blinks while the remote
controller is starting up or when there is an
error.
The functions of the function buttons
change depending on the screen. Refer to
the button function guide that appears at
the bottom of the LCD for the functions
they serve on a given screen.
When the system is centrally controlled,
the button function guide that corresponds
to the locked button will not appear.
Main display
Main menu
Fri
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Cool
Set temp.
Weekly timer
OU silent mode
Main display:
Mode
Temp.
Fan
Cursor
Page
7
8
9
0
7
8
9
0
Function guide
7 Function button F1
Main display: Press to change the operation
mode.
Main menu: Press to move the cursor
down.
8 Function button F2
Main display: Press to decrease
temperature.
Main menu: Press to move the cursor up.
9 Function button F3
Main display: Press to increase
temperature.
Main menu: Press to go to the previous
page.
0 Function button F4
Main display: Press to change the fan
speed.
Main menu: Press to go to the next page.
5

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

P72nmhu-e-oaP48nmhu-e-oaP96nmhu-e-oa