Failures Research - Planet 152 Série Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Planet 152 / 152 ATEX / 152 FC / 152 FC ATEX / 152 1.1 / 152 1.1 ATEX / 1/50 OPT

8.7 - Failures research

FAILURE
THE VACUUM CLEANER DOES
NOT START
THE VACUUM CLEANER IS TOO
NOISY
(the head issues very strong
vibrations)
THE VACUUM CLEANER DOES
NOT SUCK THE DIRT
THE VACUUM CLEANER INPUTS
DUST
THE VACUUM CLEANER FEATURES
ELECTROSTATIC CHARGES ON THE
FRAME OR ON THE SUCTION HOSE
34
CAUSE
Lack of voltage
Excessive dirt deposit on the motors
turbines (eventual breaking or
misfunctioning of the filter)
- Obstructed filter
- The suction hose is obstructed
- Gaskets seal
Breaking or misplacement of
the filter
Lack of or bad grounding
SOLUTION
- Check that the voltage is present in the socket
- Check if the plug and the cable are undamaged
- Ask assistance to an authorised technician
Ask authorised technical assistance
-Turn off the vacuum cleaner and shake/
replace the filter.
- Turn off the vacuum cleaner and clean/
replace the suction hose.
- Turn off the vacuum cleaner and check the
efficiency of the tank gaskets
Turn off the vacuum cleaner and replace the
filter or place it again correctly, after having
carried out a careful cleaning.
Turn off the vacuum cleaner and check the
efficiency of the grounding of the electrical
feeder. Make sure that you are using an
antistatic suction hose.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

152 atex série152 fc152 fc atex152 1.1152 1.1 atex1/50 opt

Table des Matières