Electrical Installation; Water Installation - DURAVIT SensoWash 09372000 Série Notice De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6

Electrical installation

Power supply
# 610... .. 2 .. ....
Power supply
# 610... .. 1 .. ....
Max. rated power
Circuit breaker
RCCB
Protection type
Protection class
Position of electrical connection
IG 1/2"
60 mm
2
/
"
3
8
Pre-installation
> Lay a permanent power supply line:
Please observe the position of the electrical
connection
Leave at least 800 mm (31½") of feed cable exposed
> Install circuit breaker
Connect a separate upstream circuit breaker
Connect an upstream residual current device (RCD)
separating all poles
> Appliances have to be correctly earthed.
14
Connecting the cable (Diagram 14)
> Please observe the L, N and PE conductors.
16
Installing junction box (Diagram 16)
> Fix the junction box in the toilet in the designated
place.
220 – 240 V ~ 50/60 Hz
100 – 120 V ~ 50/60 Hz
1.65 kW
I
= 16 A
N
I
= 30 mA
N
IP X4
1
60 mm
2
/
"
3
8

Water installation

Cold water
DN 15(1/2")
Water
0.07 – 0.75 MPa
pressure
(10 – 109 psi)
Water
max. 2.4 mmol/l (240 ppm)
hardness
NOTE!
> Install a water softener with water
hardness ≥ 2.4 mmol/l (≥ 240 ppm).
Pre-installation
> Install the water connection and water outlet in the
specified areas.
DANGER!
Health risk and potential product damage.
> Supply the Shower WC with cold drinking water from
the main water system.
> Do not connect any waste water, grey water, industrial
water, sea water or other untreated or semi-treated
water.
7
Connecting the water (Diagram 7)
NOTE! Avoiding any malfunctions!
> Only use the water supply hoses provided.
SensoWash_MAL_2pWC_54041/15.01.4
5