7.1.3

Adapting to different supply voltages

Take note of the machine's supply voltage, machines are normally
provided with a 400V – 3 (three phase) 50 Hz supply except when other
supply specification are requested at the time of order.
Warning! To adapt the equipment for functioning with supply
voltages different from those indicated on the following modifications must
be carried out.
1) Adjust the operating voltage on the electrical board
2) Substitute the motor with one for the new requested voltage
3) Application of a new label
Carry out all three modifications with care. Only in this way can
the equipment be considered safe.
1) Adjust the operating voltage on the electrical board
Remove the plug from the mains and open the machine's electrical
cabinet. Modify the jumper with the specific terminal (see electrical
diagram, chapter 7.3, and the machine mounted board) according to the
voltage to be obtained.
2) Substitute the motor
Request/order a suitable motor for the voltage to be obtained.
Subsequently make the connection following the electrical diagram
(chapter 7.3).
3) Application of a new label.
Update the indications shown on the plaque by applying a similar
indelible plate showing the data for the new electrical supply.
For voltage modifications different from standard 230V and 400V
(single or three phase) ask the Manufacturer.

7.2 Exploded diagrams

To make it simpler to find the cause of faults and if necessary to
substitute damaged parts, exploded diagrams of the equipment are shown
below with reference to each component.