3.5 SENSOR Auto-Off
(LED Standard and LED Sensor are on)
For flame ignition, activate the DoubleClick IR-Sensor (6) by passing you hand over it twice.
(see paragraph 4.4) The flame is extinguished automatically when the adjusted burning
time expires (factory setting: 5 sec). Alternatively the flame can be extinguished by a short
push on the function knob (1).
The burning time can be adjusted with the learn function "SENSOR Auto-Off burning time"
(see paragraph 3.5.1 learn function "SENSOR Auto-Off burning time"). To activate the
learn function press the function knob (1) while the application program SENSOR Auto-Off
is selected.
3.5.1 Learn function "SENSOR Auto-Off burning time"
(LED Standard is on, LED Sensor blinks slowly)
This learn function is used to adjust the burning time for the application program SENSOR
Auto-Off. To activate the learn function press the function knob (1) while the application
program SENSOR Auto-Off is selected.
Learning the burning time: For flame ignition and to start the time measurement, activate
the DoubleClick IR-Sensor (6) by passing you hand over it twice.
When the needed burning time is reached (1 sec - 60 min) press the function knob (1) to
stop the flame.Thereby the reached burning time is memorized and the application program
SENSOR Auto-Off is selected again. Now, the memorized time is available for the application
program SENSOR Auto-Off.
3.6 Adjusting the IR-Sensor detection range
(LED Sensor blinks fast)
Turn the function knob (1) clockwise till the LED Sensor (5) blinks fast to select the function
for adjusting the IR-Sensor detection range. To modify the IR-Sensor detection range press
the function knob (1) briefly. (IR-Sensor coverage, 35 - 70 mm) Now, the IR-Sensor range
can be adjusted by turning the function knob (1) . The frequency of the blinking LED Sensor
(5) indicated the adjusted detection range.
Clockwise rotation:
Counter-clockwise rotation:
Hold the hand in front of the IR-Sensor (6) to test the adjusted IR-Sensor detection range.
When the IR-Sensor is activated by the hand the LED StartStop (4) lights up. If the required
detection range is not yet reached, modify the IR-Sensor detection range again by turning
the function knob (1) clockwise or counter-clockwise.
28
The IR-Sensor detection range
blinking of the LED Sensor (5) becomes faster.
The IR-Sensor detection range decreases and the
blinking of the LED Sensor (5) becomes slower.
increases and the