STOVE PERFORMANCE & TESTING
Mendip Stoves, The Loxton & Churchill models are tested in accordance with EN 13240.
Output
Wood Fuel
Churchill 8
7.5kW
Loxton 8
7.5kW
Churchill 10
9.5kW
Loxton 10
9.5kW
Weight & Nominal Heat Output for Wood and Smokeless Fuels
Log Length
Churchill 8
Loxton 8
Churchill 10
Loxton 10
Minimum Distance to Combustible Materials
Combustible materials should not be located where the heat dissipating through the walls of fireplaces or flues could ignite
it. Therefore when installing the stove in the presence of combustible materials due account must be taken of the guidance
on the separation of combustible material given in Building Regulations Approved Document J and also in these stove
instructions. The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove.
When installing the stove 100mm from a combustible wall behind , use the additional, rear convection panel supplied
with the stove, this slots over the rear convection panel providing additional radiant protection from the flue collar. A twin
wall insulated flue should be fitted flush to flue collar for this type of installation.
Stove Model
Churchill 8
Churchill 8 Convection
Churchill 8 Convection Logstore
Loxton 8
Loxton 8 Logstore
Churchill 10
Churchill 10 Convection
Churchill 10 Convection Logstore
Loxton 10
Loxton 10 Logstore
PLEASE NOTE THAT A MINIMUM DISTANCE OF 1350mm TO SOFT FURNISHINGS SHOULD ALWAYS BE MAINTAINED
Efficiency
CO@13%
79.3%
79.3%
81.0%
81.0%
Wood Reload
35cm
50min
35cm
50min
60cm
45min
60cm
45min
Minimum Distance to Combustible Materials
Suitable for
O₂
DEFRA Smoke
Control Zones
0.09
Yes / SE model
0.09
Yes / SE model
0.09
Yes / SE model
0.09
Yes / SE model
Weight Wood Load
1.5kg
1.5kg
2kg
2kg
REAR
100mm
100mm
100mm
100mm
100mm
100mm
100mm
100mm
100mm
100mm
6 of 36
Output Coal
Efficiency
Fuel
7.0kW
71%
7.0kW
71%
7.0kW
71.70%
7.0kW
71.70%
Coal Reload
Weight Coal (anth)
2hr
2hr
2hr
2hr
Suitable for 12mm non-
combustible floor plate
SIDES
600mm
150mm
150mm
600mm
600mm
500mm
100mm
100mm
500mm
500mm
CO@13% O₂
0.11
0.11
0.25
0.25
2.2KG
2.2KG
2.2KG
2.2KG
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES