Warranty Claims - Atlantic TidalWave Série Manuel D'utilisation

Masquer les pouces Voir aussi pour TidalWave Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Warranty Claims

• In case of warranty claims, pump should be returned to place of purchase accompanied
by original receipt.
Cleaning
Fountain pumps will require periodic cleaning of the magnetic rotor and rotor chamber.
Please follow the directions below for proper cleaning procedures:
• Remove the pre-filter.
• Remove the threaded inlet by rotating it in a counterclockwise half turn while pulling
lightly outward from the pump body.
• Remove the impeller assembly from the rotor chamber.
Note: The impeller assembly is comprised of six individual parts shown in the image below.
Take care not to lose or misplace any of these pieces during the cleaning process.
Pre-filter
Flow Adjustor
• Inspect the magnetic rotor and the rotor chamber for built up debris. Loose debris can be
flushed out with clean water. Often in hard water, well water or pond-free applications,
debris may appear as a crusty film around the rotor and in the rotor chamber. Remove
this film using a scrub brush and white vinegar.
• Inspect the intake O-ring for nicks or breaks.
• Re-assemble the impeller assembly insert it into the rotor chamber.
• Attach the threaded inlet by applying pressure and rotating it in a clockwise half turn.
• Replace the pre-filter.
Threaded
Inlet Cover
Chamber
Impeller
Assembly
Rubber Bushing
Impeller/
Magnetic Rotor
Ceramic Shaft
Friction Washer
Rotor
Pump Body/Motor
Rubber Feet
5

Publicité

Table des Matières
loading

Table des Matières