Diaphragm Cartridge Replacement
Rubber diaphragms are a wearable part that will need servicing over time. Moisture, heat and
dust will all shorten the life of the diaphragms. If a noticeable decrease in output is evident, a
simple diaphragm cartridge change will renew the performance of the air pump. Please follow
the steps below when installing replacement diaphragm cartridge(s). Please note: The TA400
requires one replace cartridge while the TA800 requires two.
Unplug the air pumps and remove the four screws on the bottom of air pump housing. Remove
the top cover taking care not to damage/ misplace the outer gasket and four O-rings that
seal the housing at the screw connections. Remove the three screws and the bracket that hold
the diaphragm cartridge in place. Unplug the outlet hose and remove the diaphragm cartridge.
Discard and install the new cartridge.
Warranty
All Typhoon Air Pumps carry a one year limited warranty. This limited warranty is extended solely to
the original purchaser commencing from the date of original purchase receipt. The following apply:
• Manufacturer will replace parts found to be defective including pump body, housing,
electric cord, and magnetic motor.
• Diaphragm cartridges are wearable parts and not covered by this warranty.
• A cut or altered power cord voids this warranty.
• A misused or abused air pump voids this warranty.

Warranty Claims

In case of warranty claims, the air pump should be returned to place of purchase accompanied by
original receipt.

Troubleshooting Guide

Always turn off power before inspecting the pump. Failure to observe this precaution can result in
a serious accident. Before ordering repairs, carefully read through this instruction booklet. If the
problem persists, contact your dealer.
Problem
Possible Cause
Power is off
Power failure
Air pump
does
not start
Voltage drop/ Overload
Power cord is not connected
Air pump is overheating
Air pump
stops after
starting
Power/Current overload
Kink/damaged tubing
Diminished
Dirty filter media
air flow
rate or
no air flow
Worn/damaged diaphragm cartridge
Air line is submerged below operating depth
4
Possible Solution
Turn power on
Check power supply or contact local power
company
Check/Replace the GFI (Ground
Fault Interrupter)
Connect power cord
Allow pump to cool
Check length/size of power cable. Check or
replace GFI
Repair/replace tubing
Clean filter media
Consult your dealer. Replace diaphragm cartridge
Raise air line to desired depth

Publicité