Elements
kitchen hood consists of the following elements
(Fig. 2):
Installation
Step-by-step appliance installation is shown on Fig.
3...
Setting the air extractor mode of operation of
the hood
In the extractor mode air is discharged to the out-
side by a special conduit. In that setting any carbon
filters shall be removed. The hood should be con-
nected to the opening discharging air to the outside
by means of a rigid or flexible conduit of
120 mm diameter, which should be purchased in a
shop selling installation materials.
A qualified installer should be commissioned to
make the connection.
Use control panel to control your cooker hood (Fig.
4a)
Control buttons (top-down)
Light
1
-
Press briefly to turn on/off the light
-
Press and hold (2s)
-
If the light is on — Timer function
-
If the light is off — change the colour of
decorative lighting and button backlight
2
Backlight colours:
-
OFF
-
red
-
green
-
blue
-
yellow
-
turquoise
-
pink
4 Speed 1 on/off
3 Speed 2 on/off
2 Speed 3 on/off
1 Speed 4 on/off
If the decorative lighting is off, the button backlight
is red.
The control panel buttons are illuminated constant-
ly. Backlight of the selected function is brighter.
Timer - press and hold (for 2 sec.) current speed
button - activation / deactivation Timer function
(auto off the hood after 10 minutes). activation of
function is shown by flashing the background of
button. If You will change the speed, Timer func-
tion will still work
INSTALLATION

OPERATION AND MAINTENANCE

Setting the odour absorber mode of operation
of the hood
In this option filtered air returns to the room
through openings in the front of the hood.
In this setting it is necessary to install the carbon
filter. It is recommended to install the air guide
(availability depending on model).
In some universal hoods you need to switch lever
inside the hood (Fig. 8) to switch between the
extraction and air recirculation modes. The cle-
aned air is returned to the room through the holes
in the top of the unit.
Furniture and telescopic cooker hoods operating
in air recirculation mode require installation of the
exhaust duct. The other end of the duct should be
directed to the room as it will discharge filtered air.
Fan speeds
The lowest and medium speeds should be used
under normal conditions and with low concentration
of fumes. The maximum speed should be used in
case of high concentration of kitchen fumes, e.g.
during frying or grilling.
Remote (Fig. 4b) - functions:
1. turn on/off the light
2. Left / right - Changing the speed
3. Up / down - Changing the light or decorative
color
4. Timer - activation / deactivation of Timer func-
tion
To use the remote control unit:
-
Insert batteries in the remote control by remov-
ing the battery compartment cover on the back
of the remote control unit.
-
Place the new batteries in the remote control
unit according to the markings inside the bat-
tery compartment.
-
Close the battery cover.
-
Point the remote control unit toward the front
of the cooker hood.
Ensure there are no obstacles between the re-
mote control transmitter and the sensor on the
cooker hood. Fluorescent light can interfere
with the remote control operation.
Hoods with a air flow rate exceeding 650m³/h fea-
ture the Eco-Boost function. When operating at the
highest speed the appliance will eventually reduce
the speed to a lower setting. The delay until the
speed is reduced depends on the model and is
given in the technical specifications