DGCI−...
9

Repairs

Recommendation: Send the product to our repair service. The necessary accu
S
rate adjustments and tests will then be taken into consideration.
Information on spare parts and assistant devices can be found under
S
www.festo.com/spareparts
Replacing cushioning elements
Note the section Accurate adjustment of the stroke" in the chapter
S
Commissioning".
10

Accessories

Please note
S Please select the appropriate accessories from our catalogue
www.festo.com/catalogue
11

Eliminating faults

LED display on measuring system
Status LED
(Power: green)
Off
Off
On
On
Flashes
Fig. 28
Festo DGCI−... 0801a English
Fault LED
(Error: red)
Off
On
Off
On
Flashes
Meaning
No voltage
Initialization fault
Normal function
Magnet not recognized or incorrect number of magnets
Operating voltage not within permissible range
41